background image

 

 

Application Drawing 

Vi2401 Ethernet Extender over Coax Installation Manual

DO NOT OPEN

RISK OF ELECTRIC SHOCK

CAUTION

CAUTION: 

TO REDUCE THE RISK OF ELECTRICAL 

SHOCK, DO NOT REMOVE COVER. NO USER 

SERVICEABLE PARTS INSIDE. REFER SERVICING TO 

QUALIFIED SERVICE PERSONNEL.

IP Camera-end Installation

The Smart Choice for Transmission Solutions                       

www.vigitron.com

The MaxiiCopper Model Vi2401 is a revolutionary data transmission device 

that extends full-duplex High-Speed Ethernet over existing coax infrastruc-

tures. For data, it extends 10BaseT signals up to 5,000 ft (1,524m) and 

100BaseT up to 1,800 ft (548m). With Pass Through PoE (PTP™), it 

extends 10Base T data 3,000 ft ( m)and 100Base T up to 1,800 ft ( m)It 

employs 

MaxiiCopper

 innovative and unique Ethernet extension 

technology that is designed to take full advantage of high-bandwidth 

networking cables and maintain a full-duplex 10 or 100 Mb/s Ethernet 

connection up to the maximum range - with minimum transmission error 

and latency.
Vi2401 can connect multiple remote network devices such as Mega-pixel IP 

cameras or VoIP to a central LAN switching fabric with ease.  Its dual-rate 

capability feature provides an easy way to balance the best possible 

network throughput and long-reach distance design.
The Vi2401 is a transceiver device and needs to be deployed on both ends 

of the coaxial cable.  A dip switch sets the data rate between the remote 

and central locations. It is equipped with LEDs to provide link status and 

configured data rate.  No IP setting or configurations are required and it is 

completely transparent to the corporate IP network and higher layer 

protocols. The Coax cable needs to be point to point without any branches. 

 Ethernet Extenders

Important Safety Warning

- Connect the chasis ground to a suitable earth ground with 18 AWG wire.

- Set the Master/Slave dip switch to “Master” mode.

- Set the 10/100 BaseT dip switch to the appropriate rate based on the 

required maximum data rate and maximum distance. 

- Set the Remote/Local switch to Remote

- Connect the IP camera RJ45 connector to the 10/100BaseT Ethernet port 

of Vi2401 using a standard Cat5/6 cable of maximum 100 m in length.

- Connect one end of the long coax cable to the BNC connector of Vi2401.
The link LED on the 10/100 connector should be “ON” to indicate proper 

connection between the camera and Vi2401. 

Ethernet Switch/NVR-end Installation

- Connect the chasis ground to a suitable earth ground with 18 AWG wire.

- Set the Master/Slave dip switch to “Slave” mode.

- Set the 10/100 BaseT dip switch to match the setting on the camera-end.

- Set the Remote/Local switch to Local.

- Connect the RJ45 connector of the Ethernet switch to the 10/100BaseT 

Ethernet port of Vi2401 using a standard Cat5/6 cable of maximum 100 m 

in length.

- Connect one end of the long coax cable to the BNC connector of Vi2401.
The link LED on the 10/100 Ethernet connector should be “ON” to indicate 

proper connection between the switch and Vi2401. Also the Traffic LED on 

the Coax side should be on and flashing to indicate proper connection.  

While the Link LED, Orange for 100BaseT and Green for 10BaseT, in a 

IP Camera

Up to 5,000 ft.

(1,515 m) Coax

Cat-5

Cat-5

Data

NVR

Network Switch

Vi2401

Vi2401

- Read these instructions.

- Keep these instructions.

- Heed all warnings.

- Follow all instructions.

- Do not use this apparatus near water.

- Clean only with a dry cloth.

- Install in accordance with the manufacturer’s instructions.

- This installation should be made by a qualified service person and should conform        

  to all local codes.

- DO NOT bundle UTP or Coax signals in the same conduit as high-voltage wiring.

- To reduce the risk of fire or electrical shock, do not expose these products to rain, 

  moisture, dripping or splashing.

- No objects filled with liquids, such as vases, shall be placed on Vigitron equipment.

- DO NOT install the unit in a place where the operating ambient temperature    

  exceeds 75° C.

- Make sure that the external power supply output voltage is in the recommended 

  range. 

- Do not install near any heat sources such as radiators, heat registers, stoves or 

  other apparatus (including DVRs) that produce heat.

- Protect the power cord from being walked on or pinched particularly at plugs, 

  convenience receptacles, and the point where they exit from the apparatus.

- Only use attachments/accessories specified by the manufacturer.

- Unplug this apparatus during lightning storms or when unused for long periods of 

  time.

- Refer all servicing to qualified service personnel. Servicing is required when the 

  apparatus has been damaged in any way, such as a power supply cord or plug is 

  damaged, liquid has been spilled, or objects have fallen into the apparatus, the 

  apparatus has been exposed to rain or moisture, does not operate normally, or has 

  been dropped.

- The mains plug is used as the disconnect device and shall remain readily operable.

        WARNING! - This apparatus is a Class I product. This product must be 

connected to a mains socket outlet thru an AC to DC Power supply.

        WARNING! - The mains plug is used as the disconnect device and shall remain 

readily operable.

        WARNING! - Surge: A ground connection is required for the external surge 

protection to work properly. In cases where the unit expected to be exposed to large 

electrical spikes, the surge protector, Vi2001, should be used on the UTP side. A 

proper coax surge protector may be needed on the coax side.

         WARNING! - To reduce the risk of fire or electric shock, do not expose this 

apparatus to rain or moisture. This apparatus shall not be exposed to dripping or 

splashing and no objects filled with liquids, such as vases shall be placed on the 

apparatus.

Reviews: