Adjusting the Humidity Level Upward
 
If the humidity reading on the hygrometer is below your desired level, slowly turn
the Control Knob clockwise until the fan starts running and close the ClimaCab
door(s).  Repeat this process every few hours until you have reached your desired
level and make adjustments in small increments.  It may take more or less than 24
hours to reach and maintain your desired level, depending on several factors.
 
Adjusting the Humidity Level Downward
 
When the fan stops running and the reading on the hygrometer is above your
desired level, slowly turn the Control Knob counter-clockwise 1/8 turn and close
the ClimaCab door.  Repeat this process every few hours until your desired humidity
level has been reached and make adjustments in small increments.
 
REMEMBER, IF YOUR SYSTEM HAS BEEN RUNNING AT A HIGHER LEVEL FOR AN
EXTENDED PERIOD OF TIME, IT MAY TAKE SEVERAL HOURS FOR THE HUMIDITY
LEVEL IN YOUR CLIMACAB TO DROP TO YOUR NEW SETTING.
 
To achieve rapid drops in humidity levels, assuming your house is lower than the
ClimaCab interior, you can open the doors and allow air exchange.
 
Maintenance
 
1.) When the red LED indicator light is on, it is time to fill the distilled water reservoir.
Frequency of filling will vary according to climatic conditions and the size of the
humidified space (between 14 and 60 days).
 
2.) Slowly fill the water reservoir with DISTILLED water until the red time-to-fill LED
turns off.  Slowly add 2½ cups (20 ounces) more water after the LED shuts off. The
reservoir is outfitted with an overflow vent that will dispense water into your
ClimaCab rather than into the electronics compartment. 