Gasifying boiler Vigas
5.1.3 Boiler active – burning phase
5.1.4 Add fuel, boiler switch-off (manual control)
5.1.5 Boiler shut down (automatic)
6.
BOILER VIGAS
Lambda Control
IN BASIC CONFIGURATION
Boiler
VIGAS
Lambda Control
operates with information about oxygen overflow in exhaust gas received from
lambda sensor to control the flap of primary and secondary air. This system allows to burn all kinds of
wood more efficiently and at the same time decrease the fuel consumption by 20-25 %.
12
The burning phase is active, when the exhaust gas temperature is
(
end) +20 °C. The pump is pulsating in this phase. If pump symbol
is flashing, pump works. Boiler is responsive to the indoor thermostat,
when indoor thermostat is switched off, boiler output is slowly reduced.
Choose one option
OFF
Switch off
Add fuel
Cancel display driver
▲
Change indicated figure
By pressing „
“ boiler fan will be switched-off and discharge fan will be
switched-on for 300 s. The time is indicated in the upeer left corner of the
display. By pressing button „+60“ is possible to extend discharge fan running
time.
Using the rod, open chimney flap, consequently open the upper
door. You can add fuel if necessary.
After reloading the fuel close the upper door and chimney flap
(pic.12.4). By pressing
„0“ discharge fan will be switched off, boiler fan will
start working automatically.
When exhaust gas temperature drops under the set up temperature (
end), the boiler is automatically switched-off. Sign „END“ will be indicated
on the display. By pressing 2 times button „ENTER“, boiler will start working
again.
Graphic control is used for this operation. To activate display driver press
short middle „ENTER“ button. Graphic control offers option to: switch-off
boiler, add fuel or cancel display driver.
Summary of Contents for 100 Lambda Control
Page 5: ...Gasifying boiler VIGAS 5 ...