POWER SUPPLY
Internal Power Supply
Part Number: FSP035-1PI01
Input Voltage Range
90 TO 264 VAC
Input Frequency Range
47.5 TO 63 HERTZ
Short Circuit Protection
Output can be shorted without damage
Over Current Protection
3.5 A typical at 12.0 VDC ( Protect when
short circuit )
Leakage Current
0.75mA (Max) at 264VAC / 50Hz
EFFICIENCY
77 % typical at 115VAC Full Load
Fuse
Internal and not user replaceable
Power Dissipation
35 Watts (typ)
Max Input AC Current
1.2 Arms @ 90VAC, 0.7 Arms @265VAC
INRUSH CURRENT (COLD START)
60 A @ 115VAC
Power Supply Cold Start
Shall start and function properly when
under full load, with all combinations of
input voltage, input frequency, and
operating temperature
Power Supply Transient Immunity
Shall be able to withstand an ANSI/IEEE
C62.41-1980 2000V 200 ampere ring wave
transient test with no damage
Power Supply Line Surge Immunity
Shall be able to withstand 1.5 times
nominal line voltage for one cycle with no
damage
Power Supply Missing Cycle Immunity
Shall be able to function properly, without
reset or visible screen artifacts, when ½
cycle of AC power is randomly missing at
nominal input
Power Supply Acoustics
The power supply shall not produce audible
noise that would be detectable by the user.
Audible shall define to be in compliance with
ISO 7779 (DIN EN27779:1991)
Noise measurements of machines acoustics
Power Switch noise shall not be considered
US Type Power Cable
Separate 3-prong NEMA 5-15P type plug.
Length = 1.8m. Connects to display.
Color = Black
European Type Power Cable
Schuko CEE7-7 type plug.
Length = 1.8m, Connects to display.
Color = Black
CCC Type Power Cable
Separate 3-prong type plug.
Length = 1.8m. Connects to display.
Color = Black
PSE Type Power Cable
Separate 2-prong NEMA 1-15P type plug.
Length = 1.8m. Connects to display.
Color = Black
Power Saving Operation(Method)
VESA DPMS Signaling
ON Mode < 40 W (Max) / 38 W (Typ)
Power Consumption
On Mode < 40 W (Max) / 38W (Typ)
Saving Mode < 2 W, Off Mode < 1 W
Recovery Time
On Mode = N/A, Active Off < 3 sec
6
ViewSonic
Corporation
Co
nfidential
-
Do
Not
Copy
VX922-1
Summary of Contents for VX922-1
Page 57: ...Step 2 Press Write to IC icon 54 ViewSonic Corporation Confidential Do Not Copy VX922 1...
Page 61: ...Please press 58 ViewSonic Corporation Confidential Do Not Copy VX922 1...
Page 64: ...Write DDC to IC Step 1 Select 24C02 61 ViewSonic Corporation Confidential Do Not Copy VX922 1...
Page 66: ...Step 2 Press Write to IC icon 63 ViewSonic Corporation Confidential Do Not Copy VX922 1...
Page 83: ...3 Monitor white screen 80 ViewSonic Corporation Confidential Do Not Copy VX922 1...
Page 84: ...4 Monitor black screen 81 ViewSonic Corporation Confidential Do Not Copy VX922 1...
Page 92: ...9 Block Diagram 89 ViewSonic Corporation Confidential Do Not Copy VX922 1...
Page 93: ...90 ViewSonic Corporation Confidential Do Not Copy VX922 1...