2. Specification
4-1 GENERAL specification
Test Resolution & Frequency
1680x1050 @ 60Hz
Test Image Size
Full Size
Contrast and Brightness Controls
Factory Default:
Contrast = 70%, Brightness = 100%
4-2 VIDEO
INTERFACE
Analog Input Connector
DB-15 (Analog), refer the appendix A
Digital Input Connector
DVI-D (Digital), refer the appendix B
Default Input Connector
Defaults to the first detected input
Video Cable Strain Relief
Equal to twice the weight of the monitor for five
minutes
Video Cable Connector DB-15 Pin out
Compliant DDC 1/2B
Video Signals
1. Video RGB (Analog)
Separate, Composite, and Sync on Green
2. TMDS (Digital)
Video Impedance
75 Ohms (Analog), 100 Ohms (Digital)
Maximum PC Video Signal
950 mV with no damage to monitor
Maximum Mac Video Signal
1250 mV with no damage to monitor
Sync Signals
TTL
DDC 1/2B
Compliant with Revision 1.3
Sync Compatibility
Separate Sync, Composite Sync, SOG
Video Compatibility
Shall be compatible with all PC type computers,
Macintosh computers, and after market video cards
Resolution Compatibility
640 x 350*, 640 x 480, 720 x 400* (640 x 400*), 800 x
600, 832 x 624, 1024 x 768, 1152 x 864, 1152 x 870,
1280 x 720, 1280 x 960, 1280 x 1024 , 1400 x 1050 ,
1440 x 900 , 1600 x 1200, 1680 x 1050
* The image vertical size might not be full screen.
But the image vertical position should be at the center.
Exclusions
Not compatible with interlaced video
4-3 POWER
SUPPLY
Internal Power Supply
Part Number: HJC- H0AU032001
INPUT VOLTAGE RANGE
AC100~240 (WORLDWIDE)
Input Frequency Range
47 TO 63 HERTZ
Short Circuit Protection
Output can be shorted without damage
Over Current Protection
5A TYPICA
L
AT 5 VDC ( Protect when short circuit )
Leakage Current
3.5mA (Max) at 264VAC / 50Hz
EFFICIENCY
80 % typical at 115VAC Full Load
75% minimum at 115VAC Full Load
Fuse
Internal and not user replaceable
Power Dissipation
< 48 Watts (typ)
Max Input AC Current
1.5Arms @ 90VAC , 0.75Arms@ 180VAC
INRUSH CURRENT (COLD START)
50A MAX./ 115V
AC
/ 60HZ
(COLD START AT 25
℃
,FULL LOAD)
90A MAX./ 230V
AC
/ 50HZ
(COLD START AT 25
℃
,FULL LOAD)
Power Supply Cold Start
Shall start and function properly when under full load,
with all combinations of input voltage, input frequency,
and operating temperature rms
Power Supply Transient Immunity
Shall be able to withstand an ANSI/IEEE C62.41-1980
Summary of Contents for VS11435
Page 38: ...ViewSonic Corporation Confidential Do Not Copy VX2035wm 1 35 6 Troubleshooting Flow Chart ...
Page 39: ...6 1 NO POWER 6 2 MCU NO FUNCTION ViewSonic Corporation Confidential Do Not Copy VX2035wm 1 36 ...
Page 40: ...6 3 NO DISPLAY ViewSonic Corporation Confidential Do Not Copy VX2035wm 1 37 ...
Page 41: ...ViewSonic Corporation Confidential Do Not Copy VX2035wm 1 38 7 Block Diagram ...
Page 52: ...9 2 MAIN PCB BOTTOM VIEW ViewSonic Corporation Confidential Do Not Copy VX2035wm 1 49 ...
Page 54: ...9 5 POWER PCB TOP VIEW ViewSonic Corporation Confidential Do Not Copy VX2035wm 1 51 ...
Page 55: ...9 6 POWER PCB BOTTOM VIEW ViewSonic Corporation Confidential Do Not Copy VX2035wm 1 52 ...
Page 57: ...ViewSonic Corporation Confidential Do Not Copy VX2035wm 1 54 ...