ViewSonic Corporation
Confidential - Do Not Copy
29
Modes switching
check
1. Use Chroma Pattern Generator to make sequence.
VESA (640x480 800x600 1024x768 1280x1024), MAC
832x624 DOS (640x350 720x400), the detail supported
modes and power saving signal.
2. Confirm the above timing modes must be full screen and
the picture must be normal.
3. LED is Orange at power saving mode.
Chroma Signal
Generator
Y measurement
at default setting
1. Set brightness to default value 100 and contrast to default
value 70 at 6500K
2. At full white patter, Measure Y, which should be
250+/-10cd/m² (QDI 220+/- 10cd/m²)
Chroma Signal
Generator and Color
Analyzer
Panel Flicker
check
1. Mode: 1280x1024@60Hz
2. Set Brightness& contrast to default value
3. Do “Auto Image Adjust”
4. Shut down PC to check whether there’s glitter on the center
of the picture.
Equipment::
Chroma Signal
Generator & PC
Power saving
1.
Mode: 1280x1024@60Hz
2.
Pattern: full white
3.
Brightness: Max.
4.
Contrast: Default
5.
Check power consumption at each modes
State
Power
Consumption
LED color
Normal
<
38W
Green
Stand By
<
1W
Orange
Power Key Off
<
1W
No
Chroma signal
generator and Power
meter
AC input: 230V/50Hz
VA702-2_VA721-3_VA721b-3