2. Error Message
Power Temp Lamp Status
Note
O
-
-
Stand-by
G
-
-
Powering up
G
-
-
Normal operation
O
-
-
Normal power-down cooling
O
-
-
First Lamp-Lit error cooling
Lamp Error Messages
O
-
R
Second Lamp-Lit error
-
-
R
Lamp error in normal operation
Thermal Error Messages
-
R
-
Fan 1 error (the actual fan speed is ±20% outside the
desired speed.)
Lamp Fan
-
R
R
Fan 2 error (the actual fan speed is ±20% outside the
desired speed.)
Ballast Fan
-
R
G
Fan 3 error (the actual fan speed is ±20% outside the
desired speed.)
Blower Fan
R
R
R
Thermal Sensor 1 open error (the remote diode has an
open-circuit condition.)
DMD sensor
R
R
G
Thermal Sensor 2 open error (the remote diode has an
open-circuit condition.)
G
R
R
Thermal Sensor 1 short error (the remote diode has an
short-circuit condition.)
DMD sensor
G
R
G
Thermal Sensor 2 short error (the remote diode has an
short-circuit condition.)
O
R
R
Temperature 1 error (over limited temperature)
DMD sensor
O
R
G
Temperature 2 error (over limited temperature)
-
G
R
Fan IC #1 I2C Connection error
GMT 793
Summary of Contents for PJ513D-1
Page 41: ...38 ViewSonic Corporation Confidential Do Not Copy PJ513D 1 Fig 1 15...
Page 43: ...40 ViewSonic Corporation Confidential Do Not Copy PJ513D 1 Fig 3 2...
Page 56: ...53 ViewSonic Corporation Confidential Do Not Copy PJ513D 1 Fig 10 7...
Page 58: ...55 ViewSonic Corporation Confidential Do Not Copy PJ513D 1 Fig 10 9...
Page 110: ...107 ViewSonic Corporation Confidential Do Not Copy PJ513D 1 9 PCB Layout Diagrams...
Page 111: ...108 ViewSonic Corporation Confidential Do Not Copy PJ513D 1...
Page 114: ...111 ViewSonic Corporation Confidential Do Not Copy PJ513D 1 Module 2 ASSY UPPER CASE...
Page 115: ...112 ViewSonic Corporation Confidential Do Not Copy PJ513D 1 Module 3 ASSY LOWER CASE...