9
Firmware update procedure :
When you received a received monitor , please check whether the firmware version. If not , please following procedure to
upgrade to the latest version .
1. Equipment needed :
-
W9V-Q2
-
PC ( Personal computer )
-
LPT cable
-
Fixture (LM5ISP)
-
Firmware upgrade program
2.
Connection :
To PC
To Monitor