97
Example 1: Set Brightness as 76 for Display (#02) and this command is valid
Send (Hex Format)
Name Length ID Command Type Command Value1 Value2 Value3 CR
Hex
0x38
0x30
0x32
0x73
0x24
0x30
0x37
0x36
0x0D
Reply (Hex Format)
Name Length
ID
Command Type
CR
Hex
0x34
0x30
0x32
0x2B
0x0D
Example 2: Set Brightness as 75 for Display (#02) and this command is NOT valid
Send (Hex Format)
Name Length ID Command Type Command Value1 Value2 Value3 CR
Hex
0x38 0x30
0x32
0x73
0x24
0x30
0x37
0x35
0x0D
Reply (Hex Format)
Name Length
ID
Command Type
CR
Hex
0x34
0x30
0x32
0x2D
0x0D