![background image](http://html1.mh-extra.com/html/viewsonic/cde7500/cde7500_user-manual_1020183050.webp)
41
Get-Function table
Get Function Length ID Command
Type
Command
Response Range
Comments
(ASCII)
Code (ASCII) Code (Hex) (Three ASCII bytes)
Get-Contrast
8
g
a
61
000 ~ 100
Get-
Brightness
8
g
b
62
000 ~ 100
Get-
Sharpness
8
g
c
63
000 ~ 100
Get-Color
8
g
d
64
000 ~ 100
Get-Volume
8
g
f
66
000 ~ 100
Get-Mute
8
g
g
67
000: Off
001: On (muted)
Get-Input
select
8
g
j
6A
000~
See Set-function
table
Get-Power
status:
ON/ STBY
8
g
l
6C
001: ON
000: STBY
Exclude VT2405-1,
and VT3205
Get-Remote
control
8
g
n
6E
000: Disable
001: Enable
Gets RCU mode
status
Get-Power
lock
8
g
o
6F
000: Unlock
001: Lock
Get-Button
lock
8
g
p
70
000: Unlock
001: Lock
Get-Menu
lock
8
g
q
71
000: Unlock
001: Lock
Get-ACK
8
g
z
7A
000
This command is
used to test the
communication link
Get-Power
on/off log
8
g
1
31
000
(See below
example)
For specific models
only
Get-Date:
Year
8
g
2
32
Y00~Y00
Last 2 digits
(20)17~(20)99
Get-Date:
Month
8
g
2
32
M00~M00
2 digits
Get-Date:
Day
8
g
2
32
D00~M00
2 digits
Get-Time:
Hour
8
g
3
33
H00~H00
24-hr format. 2 digits
Get-Time:
Min
8
g
3
33
M00~M00
2 digits
Get-Time:
Sec
8
g
3
33
S00~S00
2 digits
Get-Device
name
8
g
4
34
000
Get-MAC ad-
dress
8
g
5
35
000
(see below
example)
For the model with
LAN
Get-RS232
version
8
g
6
36
000
(see below
example)
Version 0.0.1~9.9.9