24
Mute
8
s
6
36
000: OFF
001: ON (mute)
Button Lock
8
s
8
38
000 : Unlock
001 : Lock
Menu Lock
8
s
>
3E
000 : Unlock
001 : Lock
Key Pad
8
s
A
41
000 : UP
001 : DOWN
002 : LEFT
003 : RIGHT
004 : ENTER
005 : INPUT
006 : MENU/EXIT
Remote Control
8
s
B
42
000: Disable
Disable:
RCU has no
effect on Monotor.
001: Enable
Enabled:
RCU controls
the Monitor. This is the
power up default on the
Monitor.
002: Pass through
Pass through:
RCU
has no effect on
Monitor and all RCU
command codes are
transmitted to PC via
the RS232 port.
Factory reset
8
s
~
7E
0
Rests Monitor to
factory setting
Get function table:
Get Function Length
ID
Command
Type
Command
Value Range
Comments
Code (ASCII)
Code (Hex)
(Three ASCII bytes)
Get-Contrast
8
g
a
61
000 ~ 100
Gets Contrast value
Get-Brightness
8
g
b
62
000 ~ 100
Gets Brightness value
Get-Sharpness
8
g
c
63
000 ~ 100
Gets Sharpness value
Get-Color
8
g
d
64
000 ~ 100
Gets Color value
Get-Tint
8
g
e
65
000 ~ 100
Gets Tint value
Get-Volume
8
g
f
66
000 ~ 100
Gets Volume value
Get-Mute
8
g
g
67
000: OFF (unmuted)
001: ON (muted)
Gets Mute ON/OFF
status
Get-Input select
8
g
j
6A
000~
See Set-function table
Get-Power
status : ON/
STBY
8
g
l
6C
000: STBY
001: ON
Get-Remote
control
8
g
n
6E
000 : Disable
001 : Enable
002 : Pass through
Get-Power Lock
8
g
o
6F
000 : Unlock
001 : Lock
Get-Button Lock
8
g
p
70
000 : Unlock
001 : Lock
Get-Menu Lock
8
g
q
71
000 : Unlock
001 : Lock
Get-ACK
8
g
z
7A
000
This command is
used to test the
communication link.