31
Reply (Hex Format)
Name
Length
ID
Command Type Command Value1 Value2 Value3
CR
Hex
0x38
0x30
0x35
0x72
0x62
0x30
0x36
0x37
0x0D
Example2: Get Brightness from TV-05 , but the Brightness command ID is error
and it is NOT in the command table.
Send (Hex Format)
Name
Length
ID
Command Type Command Value1 Value2 Value3
CR
Hex
0x38
0x30
0x35
0x67
0XD3
0x30
0x30
0x30
0x0D
Reply (Hex Format)
Name
Length
ID
Command Type
CR
Hex
0x34
0x30
0x35
0x2D
0x0D
Get-function table
Set Function Length ID Command
Type
Command
Value Range
(Three ASCII bytes)
Comments
Code (ASCII) Code (Hex)
Get-Contrast
8
g
a
61
000 ~ 100
Get-Brightness
8
g
b
62
000 ~ 100
Get-Sharpness
8
g
c
63
000 ~ 100
Get-Color
8
g
d
64
000 ~ 100
Get-Tint
8
g
e
65
000 ~ 100
Get-Volume
8
g
f
66
000 ~ 100
Get-Mute
8
g
g
67
000: Off
001: On (muted)
Get-Input select
8
g
j
6A
000~
See Set-function
table
Get-Power
status: ON/
STBY
8
g
l
6C
001: ON
000: STBY
Get-Remote
control
8
g
n
6E
000: Disable
001: Enable
002: Pass through
Gets RCU mode
status
Get-Power lock
8
g
o
6F
000: Unlock
001: Lock
Get-Button lock
8
g
p
70
000: Unlock
001: Lock
Get-Menu lock
8
g
q
71
000: Unlock
001: Lock
Get-Setup
wizard
8
g
s
73
000: Disable
001: Enable
Get-ACK
8
g
z
7A
000
This command is
used to test the
communication link.
Summary of Contents for CDE3200-L
Page 50: ......