ViewSonic
CD4620
49
5.3 Get-Function
Listing
The PC can interrogate the LCD Monitor for specific information. The Get-Function packet format
consists of 5 bytes which is similar to the Set-Function packet structure. Note that the “Value” byte is
always = 00.
Get-Function description:
Length:
Total Byte of Message excluding “CR”
TV ID
Identification for each of TV
Command Type
Identify command type,
“g” (0x67h) : Get Command
Command:
Function command code: One byte ASCII code
Value[1~3]:
Three bytes ASCII that defines the value
CR
0x0D
Get-Function format
Send: (Command Type=”g”)
Name
Length
ID
Command Type
Command
Value1
Value2
Value3
CR
Byte
Count
1 Byte
2 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
Bytes
order
1 2~3
4
5
6 7 8 9
Reply: (Command Type=”r” or “-”)
If the Command is valid, Command Type =”r”
Name
Length
ID
Command Type
Command
Value1
Value2
Value3
CR
Byte
Count
1 Byte
2 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
Bytes
order
1 2~3
4
5
6 7 8 9
If the Command is Not valid, Command Type=”-“
Name
Length ID Command
Type
CR
Byte
Count
1 Byte
2 Byte
1 Byte
1 Byte
Bytes
order
1 2~3
4
5
Example1: Get Brightness from TV-05 and this command is valid.
The Brightness value is 67.
Send (Hex Format)
Name
Length
ID
Command Type
Command
Value1
Value2
Value3
CR
Hex
0x38 0x30
0x35
0x67 0x62 0x30 0x30 0x30 0x0D
Reply(Hex Format)
Name
Length
ID
Command Type
Command
Value1
Value2
Value3
CR
Hex
0x38 0x30
0x35
0x72 0x62 0x30 0x36 0x37 0x0D
Example2: Get Brightness from TV-05 , but the Brightness command ID is error
and it is NOT in the command table.
Send (Hex Format)
Name
Length
ID
Command Type
Command
Value1
Value2
Value3
CR
Hex
0x38 0x30
0x35
0x67 0XD3 0x30 0x30 0x30 0x0D
Reply (Hex Format)
Name
Length ID Command
Type
CR
Hex
0x34 0x30
0x35
0x2D 0x0D
Downloaded From TV-Manual.com Manuals