KEN002VAC
v1• 11.11.2020
Viesta Model
indoor/outdoor unit model name
VAC-09CH/VAC-09H
VAC-12H/VAC-12CH
VAC-18CH/VAC-18CH VAC-24CH/VAC-24CH
Sound power level (inside)
Sound power level (outside)
50 dB(A)
60 dB(A)
50 dB(A)
60 dB(A)
53 dB(A)
65 dB(A)
54 dB(A)
67 dB(A)
Refrigerannt R32 GWP 675
Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global
warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to
675. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 675 times
higher than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product
yourself and always ask a professional.
Cooling mode
SEER
6.3
6.1
6.1
6.5
Energy efficiency class
A++
A++
A++
A++
Design load (Pdesignc)
2.6 KW
3.4 KW
5.1 KW
6.8 KW
Energy consumption
Actual energy consumption will depend on how the
appliance is used and where it is located
144 KWh per year.
based on standard
test results
195 KWh per year.
based on standard
test results
293 KWh per year.
based on standard
test results
366 KWh per year.
based on standard
test results
Heating mode (average)
SCOP
4.0
4.0
4.0
4.1
Energy efficiency class
A+
A+
A+
A+
Design load (Pdesignh)
2.1 kW (-10°C)
2.4 kW (-10°C)
4.5 kW (-10°C)
5.5 kW (-10°C)
Declared capacity
2.0 kW (-10°C)
2.3 kW (-10°C)
4.3 kW (-10°C)
5.3 kW (-10°C)
Backup heating capacity
0.1 kW (-10°C)
0.1 kW (-10°C)
0.2 kW (-10°C)
0.2 kW (-10°C)
Energy consumption
Actual energy consumption will depend on how the
appliance is used and where it is located
735 KWh per year.
based on standard
test results
840 KWh per year.
based on standard
test results
1575 KWh per year.
based on standard
test results
1878 KWh per year.
based on standard
test results
Heating mode (warmer) optional
SCOP
-
-
-
-
Energy efficiency class
-
-
-
-
Design load (Pdesignh)
- (2°C)
- (2°C)
- (2°C)
- (2°C)
Declared capacity
- (2°C)
- (2°C)
- (2°C)
- (2°C)
Backup heating capacity
- (2°C)
- (2°C)
- (2°C)
- (2°C)
Energy consumption
Actual energy consumption will depend on how the
appliance is used and where it is located
- KWh per year.
based on standard
test results
- KWh per year.
based on standard
test results
- KWh per year.
based on standard
test results
- KWh per year.
based on standard
test results
Heating mode (colder) optional
SCOP
-
-
-
-
Energy efficiency class
-
-
-
-
Design load (Pdesignh)
- (-22°C)
- (-22°C)
- (-22°C)
- (-22°C)
Declared capacity
- (-22°C)
- (-22°C)
- (-22°C)
- (-22°C)
Backup heating capacity
- (-22°C)
- (-22°C)
- (-22°C)
- (-22°C)
Energy consumption
Actual energy consumption will depend on how the
appliance is used and where it is located
- KWh per year.
based on standard
test results
- KWh per year.
based on standard
test results
- KWh per year.
based on standard
test results
- KWh per year.
based on standard
test results
TECHNICAL SPECIFICATIONS