6.
d
to confirm; the display
shows "
FROST
" and the
temperature flashes.
7.
a
/
b
until the required value is
displayed.
8.
d
to confirm; "
END
" is dis-
played.
9.
Turn the rotary selector to the
required program.
Setting an individual time program (P3)
Setting the switching points for the heating periods
Set switching points for the whole
week.
For each switching time, enter the
time and the temperature (standard/
reduced room temperature, frost pro-
tection temperature) (see example).
You can select up to 26 switching
points.
There are different input options:
&
"MO
–
FR"
the same switching
points for Monday to Friday
&
"SA/SU"
the same switching points
for Saturday and Sunday
&
"DAILY"
the same switching points
for every day
&
"SINGLE DAY"
different switching
points for single days
Should you wish to change the
selected switching points for single
days, first delete the set switching
points for that day. Then enter the
new switching points for the individual
day (
"SINGLE DAY"
).
Example
From Monday to Friday and on Sun-
day, you want to heat from 8:00 to
22:00 h and on Saturday from 9:00 to
23:00 h with standard room tempera-
ture; the rest of the time you want to
heat with reduced room temperature.
Setting a permanent room temperature
(cont.)
12
Adjusting the room temperature
55
92
466
GB