30
Information regarding fitting lead
flashing:
■ The roof surface must be dry and free
from dust and separating agent. The
temperature throughout the work
should be between 5 and 30 °C.
■ Secure with wire nails (in "Connecting
parts" packaging unit).
■ Peel coating strip from butyl tape and
press onto lead flashing.
Note
The butyl tape is already attached in
the case of barrel roof tiles.
Overlap lead flashings approx.
150 mm (observe sealing strip).
wE
150
5.
wR
tQ
30
tQ
4.
15
250
G
On step 5: With barrel roof tiles the butyl tape should be affixed to the tiles
sepa-
rately
.
Fitting the drain panels and lead flashing
(cont.)
5604 068 GB