5
NAMA KOMPONEN & BENTUKNYA
Perangkat terdiri dari Housing, wadah tekanan, pengontrol, katup bypass, union, pipa pembuangan
dan bagian lainnya
ID
Vitopure S2-2T
Vitopure S2-3T
Water outlet
Water outlet
Water inlet
Water inlet
Upper cove
Upper cove
Controller display
Controller display
Control key
Control key
Housing
Vitopure S3-2T
Vitopure S3-3T
Water outlet
Water inlet
Upper cove
Controller display
Controller display
Control key
Control key
Housing
Water outlet
Water inlet
Upper cove
Salt feeding opening cover
Salt feeding opening cover
24
System language, unit of measurement, hardness unit and
smart cleaning can be set here.
Other mode options are default, please do not modify, so as
not to affect the normal use of the product and water quality.
Press and hold the MODE key for 3 seconds to unlock, then
press and hold the MODE key and the OK key for 5 seconds
to enter into the editing state.
Edit the parameter by pressing the Up key
▲
or Down key
▼
.
Press the OK key to confirm the storage and enter into the next entry.
Control operation
General settings S3-Series
Note
LANGUAGE
ENGLISH
UNITS
METRIC
SMART
CLEAN
OFF
Please chose language
Please choose metric
Please select “On”, set the number of monitoring days and
smart cleaning period. The number of monitor days is every 7 days
and each backwashing lasts 10 minutes by default. If water
consumption is not monitored for 7 consecutive days, a 10-minute
backwashing process will be performed at 02:00 by default at the
next regeneration time to maintain the gap between filter media
and avoid the filter media from agglomeration due to no
use in a long time.
PROGRAMMING
COMPLETE
Regeneration refers to the process of salt absorption,
slow washing, backwashing, flushing and make water
replenishment the filter material after the whole-house
central water purifier is used for a period or a certain flow
rate is used.
During brine draw, the regenerated brine in the salt tank
is sucked through the salt suction valve in the salt well.
The water flow direction is counter-current during the slow
washing of salt, i.e. the regenerated brine flows upward
from the bottom of the tank.
During backwashing, the incoming water enters from the
purification port, then backwashes the dirt on the surface
of the filter element and drains it from the sewage outlet.
During flushing, the incoming water enters from the water
inlet, then backwashes the dirt on the surface of the filter
element and drains it from the sewage outlet.
During water replenishment, water is filled into the salt
tank through the salt suction valve.
Note
Clear water consumption
records
■
This setting can clear the system water consumption records.
■
The product may have a value for detection when it leaves
the factory.
■ P
lease remove it before first use.
■ I
n the standby interface, press the down key
▼
until the
cumulative water consumption interface appears.
■ P
ress the OK button to confirm for 5 seconds to clear the
system water consumption record.
Press the MODE button to return to the standby interface.
TOTAL TREATED
80L
TOTAL TREATED
0L