14
Pump Information
IMPORTANT
Pump selection must be based on accurate system flow
and pressure drop calculations (includes DHW sizing).
Sizing of Low-Loss Header in a Residential Single-Boiler Application
*
1
For system
U
t < 20°F (
11ºC) use low-loss header sizes for
U
t 20°F (11ºC).
*
2
Low-Loss temperature sensor - is included with the boiler for use in single-boiler applications.
Boiler
Model
No. of
Boilers
Boiler
Max.
Flow
Rate
GPM
(L/h)
Typical System Flow Rates
Viessmann
Low-loss
Temp.
Sensor
Required*
2
U
t
*1
°F
(°C)
20
(11.0)
25
(13.9)
30
(16.8)
35
(16.1)
40
(13.4)
B2TB
19
1
6.2
(1400)
System Flow
Rate
LLH Required
LLH Model
GPM
(L/h)
6.4
(1453)
Yes
80/60
5.1
(1163)
Optional
80/60
4.3
(969)
Optional
80/60
3.7
(830)
Optional
80/60
3.2
(727)
Optional
80/60
included
B2TB
35
1
6.2
(1400)
System Flow
Rate
LLH Required
LLH Model
GPM
(L/h)
11.7
(2657)
Yes
80/60
9.4
(2126)
Yes
80/60
7.8
(1771.6)
Yes
80/60
6.7
(1518)
Yes
80/60
5.9
(1328)
Optional
80/60
included
Note:
The Vitodens 222-F comes equipped with a factory preset integrated boiler pump.
Vitodens 222F B2TB 19-35 are equipped with a boiler/
system pump. The system pump flow must be selected
on
U
t. If the system flow exceeds the boiler’s maximum
flow rate , a low-loss header is strongly recommended.
Low-Loss Header Application
Heating Circuit
Vitodens 222-F, B2TB 19 and 35 Technical Data
Summary of Contents for Vitodens 222-F B2TB
Page 2: ......
Page 4: ...IV ...
Page 10: ...6 ...
Page 14: ...10 Technical Data Vitodens 222 F B2TB 19 and 35 Technical Data ...
Page 29: ...25 Application 1 Operational Setup continued Notes Comments ...
Page 33: ...29 Application 2 Operational Setup continued Notes Comments ...
Page 37: ...33 Application 3 Operational Setup continued Notes Comments ...
Page 41: ...37 Application 4 Operational Setup continued Notes Comments ...
Page 45: ...41 Application 5 Operational Setup continued Notes Comments ...
Page 49: ...45 Application 6 Operational Setup continued Notes Comments ...