10
*1 Output based on 140ºF (60ºC), 120ºF (49ºC) system supply/return temperature.
*2 Net AHRI rating based on piping and pick-up allowance of 1.15.
*3 If the gas supply pressure exceeds the maximum gas supply pressure value, a separate gas pressure regulator
must be installed upstream of the heating system.
*4 See “Waterside Flow” starting on page 8 in this manual.
19, 68
26, 94
35, 125
45, 160
57, 199
B
H
2
B
W
-
0
0
2
.
o
N
l
e
d
o
M
r
e
li
o
B
CSA input Natural Gas (NG)
CSA input Liquid Propane Gas (LPG)
CSA output/DOE *1
heating capacity NG
CSA output/DOE *1
heating capacity LPG
Net AHRI rating *2
MBH
(kW)
MBH
(kW)
MBH
(kW)
MBH
(kW)
MBH
(kW)
12-68
(3.5-20)
12-68
(3.5-20)
11-64
(3.2-19)
11-64
(3.2-19)
55
(16)
19-94
(5.5-27)
19-94
(5.5-27)
18-88
(5-26)
18-88
(5-26)
77
(22)
19-125
(5.5-37)
19-125
(5.5-37)
18-117
(5-34)
18-117
(5-34)
102
(30)
32-160
(9-47)
60-160
(17.5-47)
30-149
(9-44)
56-149
(17-44)
127
(37)
32-199
(9-58)
60-199
(17.5-58)
30-185
(9-54)
56-185
(17-54)
160
(47)
Heat exchanger surface area
ft.
2
(m
2)
12.96
(1.2)
12.96
(1.2)
12.96
(1.2)
31.99
(2.9)
31.99
(2.9)
Min. gas supply pressure
Natural gas
Liquid propane gas
“w.c.
“w.c.
4
10
4
10
4
10
4
10
4
10
Max. gas supply pressure *3
Natural gas
Liquid propane gas
“w.c.
“w.c.
14
14
14
14
14
14
14
14
14
14
A.F.U.E.
%
95.0
95.0
95.0
95.0
95.0
Weight
lbs
(kg)
110
(50)
110
(50)
110
(50)
210
(95)
210
(95)
Boiler water content
USG
(L)
1.02
(3.88)
1.02
(3.88)
1.02
(3.88)
3.85
(14.6)
3.85
(14.6)
Boiler max. flow rate *4
GPM
(L/h)
6.2
(1400)
6.2
(1400)
6.2
(1400)
14.3
(3250)
14.3
(3250)
Max. operating pressure
at 210ºF (99ºC)
psig
(bar)
45
(3)
45
(3)
45
(3)
60
(4)
60
(4)
Boiler water temperature
- Adjustable high limit (AHL) range
space heating (steady state)
DHW production
- Fixed high limit (FHL)
ºF
(ºC)
ºF
(ºC)
ºF (ºC)
68 to 180
(20 to 82)
165
(74)
210 (99)
68 to 180
(20 to 82)
165
(74)
210 (99)
68 to 180
(20 to 82)
165
(74)
210 (99)
68 to 180
(20 to 82)
165
(74)
210 (99)
68 to 180
(20 to 82)
165
(74)
210 (99)
Boiler connections
Boiler heating supply and return
Pressure relief valve
Drain valve
Boiler supply/return for
indirect-fired DHW storage tank
(field supplied)
Gas valve connection
NPTM”
NPTF”
(male
thread)
NPT”
NPTF”
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
1
b
¾
¾
1
b
1
1
b
¾
¾
1
b
1
Product Information
Vitodens 200-W, Technical Data
Summary of Contents for Vitodens 200-W B2HA series
Page 1: ...Application Guide Vitodens 200 W B2HA B2HB Residential Boiler...
Page 2: ...II...
Page 4: ...IV...
Page 10: ...6...
Page 33: ...29 Vitodens 200 W Application 1 Application Code VD2X 1ZC1ZP 01 Notes Comments...
Page 39: ...35 Application 2 Operational Setup continued Notes Comments...
Page 47: ...43 Notes Comments Application 4 Operational Setup continued...
Page 55: ...51 Application 6 Operational Setup continued Notes Comments...
Page 59: ...55 Application 7 Operational Setup Instructions continued Notes Comments...
Page 77: ...73 Global presence local commitment...
Page 78: ......
Page 79: ......