Vitodens 200-W, B2HA 19 to 80 Technical Data
5683 717 - 03
22
Frame Mounting
The boiler stand is used for free-standing installation of a
single boiler within the mechanical room.
When using the boiler stand, ensure that the stand is
securely fastened to the floor (recommended concrete
expansion anchors are Hilti model KB-TZ
e
x 4 or
equivalent.
Boiler Stand for B2HA 19 to 80
The Vitodens 200-W, model B2HA does not come with
a mounting template. The wall location for the frame,
mounting bracket and all vents must be field calculated.
Boiler mounting bracket and frame
1. Attach the wall mounting bracket (supplied with the
boiler) to the boiler mounting frame using the supplied
hardware. Ensure that the wall mounting bracket is
level.
2. Move the rack into position and secure to the floor
(and to the wall if needed).