Set-up
7
Tank Set-up
(continued)
Installation of DHW tank with 120 USG / 450 liter capacity
All required components are included in the insulation jacket carton.
1.
If not already installed, fit the thermal
insulation blanket below the tank
prior to the installation of the tank
itself.
2
. Position and level the DHW tank with
its leveling bolts.
3
. Push the thermal insulation jacket at
the front onto the flange.
4.
Hook in the locking bars.
5.
Guide the thermometer sensor cable
through the provided opening and
push in the thermometer.
6.
Insert the thermometer sensor until it
bottoms out inside the sensor well,
and secure with the spring-clip.
7.
Position the insulation jacket on the
DHW tank, then fit the top panel.
8.
Press the logo (from the accessory
pack) into the lid.
9.
Cover the hole beneath the
thermometer with the cap included
in the pack.
5285
545
v1
.1
Fig 2.
Installing 120 USG / 450 ltr DHW tank