Please note
The appliance may suffer damage through the
influence of frost.
Install the heating water buffer cylinder in a
room that is free from the risk of frost and
draughts. When not in use, the heating water
buffer cylinder must be drained if there is a risk
of frost.
■
Provide adequate clearance from the wall to allow for
operation of the temperature controller (if installed).
■
Placing the heating water buffer cylinder on a plinth
will make the room easier to clean.
Installing the cylinder with an immersion heater
a
b
Fig. 1
Immersion heater installation instructions
Maintain the minimum clearance.
Note
The unheated length of any threaded immersion
heater installed on site must be at least 100 mm.
Output
Immersion heat-
er
Dim. a
Dim. b
6 kW
12 kW
min. 550 mm
min. 750 mm
min. 650 mm
min. 650 mm