Discharge side on the left
Discharge side on the right
K
M
G
B
A
D E F
H
N
D
F
E
80
810
a
b
c
532
127 117
810
686
80
d
700
h
500
K
M
G
B A
D
E
F
H
N
D
F
E
80
810
a
b
c
532
127
117
810
686
80
e
700
h
600
A
Exterior rendering
B
Wall
D
Wall duct (EPP, can be trimmed to the correct size
from the outside with a saw. Observe plaster thick-
ness)
E
Compression sealing tape and acrylic airtight
seam (all-round)
F
PU foam (all-round)
G
Appliance connector, air duct, intake side (EPP)
H
Plaster finish/wall coating
K
Hydraulic and condensate connections
M
Heat pump
N
Appliance connector, air duct on the discharge
side (EPP)
Dimension
Vitocal 350-A, type AWHI
351.A10
351.A14
351.A20
a
mm
95
85
107
b
mm
118
182
284
c
mm
522
588
689
d
mm
367
217
64
e
mm
489
489
472
g
mm
880
1020
1180
h
mm
845
995
1148
Note
Observe the
minimum room height
of 2100 mm.
Minimum clearances and dimensions for wall
installation
990
g
X
830
Q
1330
Fig. 2
Dimension
g
Q
Partition wall (if required): See the following table.
X
Distance between wall openings inside the building
Preparing for installation
Internal heat pump
(cont.)
5692878
Installation
Summary of Contents for Vitocal 350-A AWHI 351.A14
Page 82: ...82 Troubleshooting Repairs cont 5692878 Maintenance ...
Page 101: ...101 Parts list type AWHI 351 A Heat pump module cont 5692878 Components ...
Page 104: ...104 Parts list type AWHI 351 A Base frame cont 5692878 Components ...
Page 125: ...125 Parts list type AWHO 351 A Heat pump module cont 5692878 Components ...