Commissioning
26
Operating instructions for the natural gas-fuelled CHP module
VITOBLOC 200
6130329
GB
3.2.2 Measuring and setting points at the CHP module
Fig. 7
Schematic diagram of the measuring and setting points in the CHP module Vitobloc 200
item 1:
emergency stop button (in the door of the
module control panel)
item 2:
operator’s and indicator unit of the module
control
item 3:
stop cock at the additional tank for the fresh oil
item 4:
upper alternator terminal box (voltage regulator
– P1)
item 5:
alternator terminal box on the side (cos
regulator
– P1)
item 6:
revolution transducer (pick-up) of the engine
item 7:
inspection glass for the automatic lubrication oil
refill system
item 8:
vent valve for the cooling system (at the gas
separator bypass)
item 9:
transport locking device (engine feet on the
right-hand side)
item 10:
transport locking device (right alternator feet)
(viewed from the right-hand side)
item 11:
analog box
item 12:
ignition control
item 13:
Lambda probe
item 14:
transport locking device (engine feet on the left-
hand side)
item 15:
revolution transducer (pick-up) of the ignition
item 16:
cooling water temperature sensor
item 17:
ignition coils
item 18:
lubrication oil pressure sensor (oil pressure
sensor)
item 19:
starter
item 20:
actuator (governor)
item 21:
throttle gas-air mixer (governor)
item 22:
cover lid of the flywheel housing
item 23:
compensation line leading to the zero pressure
regulator
item 24:
air filter
item 25:
transport locking device (left alternator feet)
item 26:
sound hood of the thermostat
item 27:
oil level indicator
item 28:
starter battery
item 29:
drain valve for the cooling water
item 30:
filler neck for the cooling water with shut-off
valve
item 31:
pressure transducer for the cooling water
item 32:
cooling water manometer
item 33:
expansion tank for the cooling water
item 34:
dipstick
item 35:
cooling water pump
item 36:
temperature limiter
item 37:
Lambda control valve
item 38:
zero pressure regulator
item 39:
gas pressure detector
item 40:
gas manometer