10
1.
2.
3.
6.
4.
5.
7.
A
Fig. 6
A
Recess for thermometer cable
Note
The cylinder temperature sensor is supplied in the control unit pack.
0
1.
Insert the cylinder temperature sensor as far as it
will go into the opening of the clamping device.
0
2.
Hand-tighten the cylinder temperature sensor with
the screw provided.
Note
Hold the cylinder temperature sensor in place in
the sensor terminal until the screw is screwed in.
!
Please note
Overtightening the fixing screw may dam-
age the cylinder temperature sensor.
Torque: Max. 2 Nm
0
3.
Remove the top cover.
0
4.
Clamp the thermometer sensor in the clamping
bracket.
0
5.
Guide the thermometer cable through the groove
in the thermal insulation and the hole in the sheet
steel casing.
0
6.
Secure the thermometer (accessory) to the wall.
Installation instructions for wall thermometer
0
7.
Refit the top cover.
Note
The recess
A
in the top cover is intended for the
thermometer cable.
0
8.
For heating water flow temperatures in excess of
95
º
C, remove the pipe collars from the pipe out-
lets (pipe collars have l.h. threads).
0
9.
If no immersion heater is being installed, seal the
front female connection with the plug supplied and
fit the cover.
10.
Affix supplied type plate to the back of the cylin-
der.
Installation sequence
Fitting the cylinder temperature sensor and thermometer sensor (if supplied)
6150632
Installation