background image

3

6167225 GB

Safety instructions for operating the device

  

Danger

 

Hot surfaces can cause burns.

 

■   

  Do not open the appliance.

  

■   

  Do not touch the hot surfaces of 

uninsulated pipes and fittings.

Auxiliary components, spare parts 

and wearing parts

  

Caution

 

Components that were not tested 

with the appliance may damage the 

appliance or affect its function. 

Have all installation or replacement 

work carried out exclusively by 

heating contractors.

  

Danger

 

Damaged equipment poses a 

safety hazard. 

Check the appliance for external 

damage. 

Never start up a damaged 

appliance.

For your safety (cont.)

Safety instructions

■   

 All settings and work on the appliance 

must be performed as specified in 

these operating instructions. 

Further work on the appliance may be 

carried out only by authorised 

contractors.

■   

 Do not open the appliance.

■   

 Do not remove its casings.

■   

 Do not modify or remove any 

attached parts or installed 

accessories.

■   

 Do not open or retighten any pipe 

connections.

Working on the appliance

Cleaning the appliance

■   

 Clean the exterior of the appliance 

with a commercially available 

domestic cleaning agent. 

Do not use scouring agents,  

solvent-based cleaners or steam 

cleaners.

■   

 Regular maintenance ensures 

trouble-free, energy efficient, 

environmentally responsible and safe 

operation.  

Have the appliance tested and 

serviced by an authorised contractor 

at least every 3 years.

 

 

  

Danger

 

Incorrectly executed work on the 

appliance can lead to life 

threatening accidents.

 

 Work on electrical equipment may 

only be carried out by a qualified 

electrician.

Summary of Contents for ES4.A5 OK

Page 1: ...Please retain for future use Operating instructions for system users 6167225 GB 11 2020 Vitotherm ES4 Version ES4 A5 K Version ES4 A5 OK Version ES4 A5 OTK Electric water heater VITOTHERM ES4 ...

Page 2: ...erial losses and environmental pollution Note Details identified by the word Note contain additional information Safety instructions explained Target group For your safety Safety instructions Safety instructions for working on the appliance The appliance may only be connected and commissioned by authorised contractors Observe the specified electrical connection requirements Modifications to the ex...

Page 3: ...pecified in these operating instructions Further work on the appliance may be carried out only by authorised contractors Do not open the appliance Do not remove its casings Do not modify or remove any attached parts or installed accessories Do not open or retighten any pipe connections Working on the appliance Cleaning the appliance Clean the exterior of the appliance with a commercially available...

Page 4: ...pliances that will obstruct the free flow of water from the water outlet Regularly descale the water outlets at the draw off points e g shower head aerator taps Use only fittings aerators and shower heads that have been recommended by the manufacturer Operating appliances in non pressurised installations Caution Incorrect ambient conditions may damage the appliance and put safe operation at risk E...

Page 5: ... a mains isolator Close the water supply pipe Notify your heating contractor If water escapes from the appliance Danger If water escapes from the appliance there is a risk of scalding Do not touch the hot water Faults on the appliance Isolate the appliance from the power supply e g at the separate fuse or a mains isolator Close the shut off valve of the cold water supply Notify your heating contra...

Page 6: ... 6 MPa Corrosion resistant stainless steel cylinder Anode does not need to be replaced on a regular basis Efficient heating module Output 2000 W DHW heating from 10 to 40 C in 5 5 min for 5 l Energy efficiency class A Very low energy loss Functional temperature control Water temperature can be variably adjusted between 23 and 70 C Types of installation Types ES4 A5 OK and ES4 A5 OTK Appliances for...

Page 7: ...tion The appliance may be damaged if operated in areas at risk from frost If there is a risk of frost drain the appliance completely Appliances installed above washbasins types ES4 A5 OK and ES4 A5 OTK Undo the connection pipe from the inlet connector cold water Open the hot water tap Appliances installed under the washbasin type ES4 A5 K Undo flexible hoses from inlet and outlet connectors hot an...

Page 8: ...emperature 4 Switch on the power supply No Fault Background Remedy 1 The appliance is not heating the water and the LED is not illuminated Power supply fault Check the fuses Fault with the rotary temperature switch Replace the rotary temperature switch Heating contractor 2 The appliance is not heating the water and the LED is illuminated Fault with the heating module Replace the appliance Heating ...

Page 9: ...ES4 A 5 OTK Contents l 5 Voltage 220 240 V Rated output W 2000 Rated current A 8 3 9 1 Temperature range C 23 70 Pressure resistance MPa 0 6 Dimensions height x width x depth mm 427 x 285 x 163 Weight dry kg 4 4 IP rating IP 24 Water connection male thread G 1 2 Water connection mixer tap G 1 2 ...

Page 10: ...10 6167225 GB ...

Page 11: ...11 6167225 GB ...

Page 12: ...rrect disposal of the product prevents potentially harmful effects on the environment which can occur due to the improper handling of waste For more information on recycling this product please contact your local government a waste disposal service or the store where this product was purchased Subject to technical modifications Copyright Viessmann Poland The reproduction copying or use of this doc...

Reviews: