Fig. 3
1.
Reconnect the DHW cylinder to the pipework.
2.
Insert
new
gaskets
A
underneath flange
cover
B
.
3.
Fit flange cover
B
with earth cable
C
and tighten
the screws with a maximum torque of 25 Nm.
4.
Push earth cable
C
onto tab
D
.
5.
Fill the DHW cylinder from the DHW side, then
tighten the flange cover with a torque of 25 Nm.
6.
Fit thermometer sensor
E
(if available).
7.
Fit flange insulation
F
and front panel
G
.
Note
Route the thermometer lead through the groove in
the flange insulation.
Checking the connections on the water side for tightness
Instructing the system user
The installer should instruct the user in the operation of
the system.