Terminals
Function
Explanation
X3.8
X3.9
P
Pressure switch, primary
circuit
and/or
Floating contact required:
■ Closed: Safety chain has continuity
■ Open: Safety chain interrupted; heat
pump shut down
■ Breaking capacity 230 V~, 0.15 A
On-site connection:
■ Connected in series if both safety com-
ponents are installed
■
Insert jumper if no safety compo-
nents are installed
Frost stat
or
Jumper
X3.17
X3.18
Fuse F1 6.3A (slow)
Controller and sensor PCB
Set the required parameters during com-
missioning; see from page 59.
Plugs F11, F17:
Nothing should be connected to plugs
F11 and F17 on site.
Sensors
Plug
Sensor
Type
F0
Outside temperature sensor; connect on site
Ni 500
(PTC)
F4
(X5.6/X5.7)
Buffer temperature sensor, top; connect on site
Pt 500
(PTC)
F13
System flow temperature sensor (with sensor well, down-
stream of heating water buffer cylinder); connect on site
Pt 500
(PTC)
F14
Flow temperature sensor, cooling circuit (direct heating
circuit A1 or separate cooling circuit); connect on site
Ni 500
(PTC)
F16
Room temperature sensor for separate cooling circuit
(requirement) or for direct heating/cooling circuit (recom-
mendation); connect on site
Ni 500
(PTC)
Installation sequence
Electrical connections
(cont.)
5601 574 GB
Installation
Summary of Contents for BWT 221.A06
Page 20: ...20 aCH 10 9 Installation sequence Siting the heat pump cont 5601 574 GB ...
Page 22: ...22 4x 18 21 4x 6x 20 2x 19 Installation sequence Siting the heat pump cont 5601 574 GB ...
Page 23: ...23 25 2x 24 4x 22 23 Installation sequence Siting the heat pump cont 5601 574 GB Installation ...
Page 28: ...28 4 1 3 2 Installation sequence Siting the heat pump cont 5601 574 GB ...
Page 71: ...71 Opening programming unit 2 2x 1 3 Troubleshooting Repairs cont 5601 574 GB Service ...
Page 122: ...122 5601 574 GB ...
Page 123: ...123 5601 574 GB ...