7
!
Please note
Do not damage the vacuum
tubes.
Do not position the cardboard
packaging vertically, do not sub-
ject it to impacts and do not walk
on it.
Install the collector with a fall (min. 2°),
i.e. the header casing must be in a higher
position.
Note
On balconies with a protruding floor
plate, observe the following clearances
between the floor plate and the lower
holes:
■ 8 vacuum tubes: min. 200 mm
■ 12 vacuum tubes: min. 360 mm
A
600
600
B
C
x
1790
170
A
Balcony outside wall
B
Supplied template
C
Supplied template moved to the
side
Vacuum tubes
x in mm
8
260
12
420
Installation sequence
Installing the collector (positioning at 90°)
5516 344 GB