![Viessmann AQUAHOME 20-N Installation And Operation Manual Download Page 20](http://html.mh-extra.com/html/viessmann/aquahome-20-n/aquahome-20-n_installation-and-operation-manual_1018584020.webp)
Salt efficiency (reduced salt
consumption) mode
When the salt efficiency (reduced salt
consumption) mode is
ON,
the
device will run the regeneration
process more often, consuming less
salt and water for the process. The
use of salt efficiency mode will
depend on the quality of water used
in the household.
Setting of this function can only
be implemented by the service
team of the supplier or
manufacturer.
Press again the
“SET” button (but do
not hold it)
– the display screen will
show
CLEAN
caption
.
Cleaning
This must be activated
(ON)
. If the
clean function is set ON, the normal
regeneration process is preceded by
a backwash cleaning and fast rinse,
enabling removal of sediments, such
as mechanical sediments from the
filtering mesh, which is located in the
main distributor. If the display screen
shows (OFF), then use the
▲
or
▼
button to change it to (ON).
Press again the
“SET” button (but do
not hold it)
– the display screen will
show
CLEAN TIME
caption
.
Duration of cleaning
The display screen will show a
flashing number, such as 6, which
indicates that duration of additional
backwash cleaning and fast rinse will
be 6 minutes. It is recommended to
set the cleaning time to one minute
as a standard. In the case when the
input water contains increased
amounts of impurities such as sand,
sludge, slurry, etc., the duration of
cleaning may be extended to a
maximum of 15 minutes. In order to
change the value on the display
screen, press the
▲
button to reduce
cleaning
duration time or
the
▼ button to
reduce it.
Press again the
“SET” button
(but do not hold
it)
– the display
screen will show
RECHARGE DAY
caption
.
Maximum period between
regenerations in days during water
uptake idle period
Automatic regeneration during water
uptake idle period helps maintaining
microbiological cleanliness of the
medium (during water uptake idle
period the medium may become a
habitat for microorganisms and
bacteria). With factory settings the
(
AUTO
) function will be inactive
which means that the device will not
regenerate during the water uptake
idle period. Press the
▲
or
▼ button
until the desired number appears on
the display screen. Available range of
settings is between 1 and 15 days
(DAY).
Press again the
“SET” button (but do
not hold it)
– the display screen will
show alternately flashing
RECHARGE
as well as 97 and OFF
captions
.
Automatic activation of
regeneration process when the ion
exchange capacity of the resin has
been used in 97%
With factory settings
(97 and OFF)
this function is not active. When
activated by pressing the
▲
or
▼
buttons (the display screen will show
alternately flashing 97 and OFF
captions) the device will activate
regeneration process each time
when the ion exchange capacity of
the resin has been used in 97%,
regardless of the time of day.
Setting of this function can only
be implemented by the service
team of the supplier or
manufacturer.
Press again (but do not hold) the
“SET” button, until the display screen
shows 12-hour or 24-hour clock
mode.
Setting clock mode (12-hour clock
or 24-hour clock)
Press the
▲
or
▼ button until the
display screen shows the desired
value, in order to 24-hour clock mode
20