19
Appliance installation
Appliance installation
5.
Electrical connection
Before performing any operations, disconnect the appliance from the
electricity mains using the external switch.
For greater safety, authorize qualified personnel to carry out a careful inspection of
the electrical system, ensuring it complies with the applicable norms in force,
because
the appliance manufacturer will not be held responsible for any damage
caused by the lack of earthing of the system or for improper wiring.
Check that the supply system is suitable for the maximum power absorbed by the
water heater (please refer to the data plate) and that the cross-section of the
electrical connection cables is suitable and complies with current laws.
The use of multi-plugs, extensions or adaptors is strictly prohibited.
It is strictly forbidden to use the piping from the plumbing, heating and gas systems
for the appliance earthing connection.
6. Starting and testing the appliance
Before powering the appliance, fill the tank up with water.
The filling is carried out by turning on the domestic mains tap and the hot water tap,
until the air is completely released.
Visually check for water leaks, including flanges, and slightly tighten it if necessary.
Turn the knob to adjust the temperature (Eco position recommended). The red color
heating LED keeps on during the water heating process. After the preset working
temperature is reached, the thermostat will stop the heating element automatically.