3 Handling

3.1

Assembly information

3.1.1

Mounting instructions

Do not remove the model from the packaging until immedi‐

ately before use.

System components may, in some cases, become damaged through

transportation and storage.

n

Check all parts.

n

Replace damaged components.

n

Do not repair damaged components.

n

Contaminated components may not be installed.

Observe the following when mounting:

n

flow direction indicator

n

use suitable tools

Choose the place of installation so that the fitting is easily

accessible and simple to operate.

For information, refer to the instructions for use of the Profipress /

Profipress XL, Sanpress / Sanpress XL and Sanpress Inox /

Sanpress Inox XL systems.

For information, refer to the instructions for use of the Profipress /

Profipress XL, Sanpress / Sanpress XL and Sanpress Inox /

Sanpress Inox XL systems.

3.2

Assembly

3.2.1

Leakage test

The installer must perform a leakage test before commissioning.

Checking system components

During assembly

Laying and fixing pipes

Length expansion

Handling

Easytop XL CRV slanted seat valve (combined free flow valve with backflow preventer) with flange connection

13 from  14

Summary of Contents for Easytop 2238.5XL

Page 1: ...potable water installation Model Year built 2238 5XL from 04 2017 en_INT Easytop XL CRV slanted seat valve com bined free flow valve with backflow pre venter with flange connection Instructions for U...

Page 2: ...Easytop XL CRV slanted seat valve combined free flow valve with backflow preventer with flange connection 2 from 14...

Page 3: ...1 Overview 9 2 3 2 Markings on components 9 2 3 3 Compatible components 10 2 3 4 Operating mode 10 2 3 5 Technical data 10 2 4 Information for use 11 2 4 1 Corrosion 11 2 5 Optional accessories 11 3 H...

Page 4: ...ega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning and advisory texts are set aside from the remainder o...

Page 5: ...the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The relevant national laws stand ards regulations di...

Page 6: ...ning execution operation and maintenance of potable water installations DIN EN 806 part 5 Planning execution operation and maintenance of potable water installations DIN EN 1717 Planning execution ope...

Page 7: ...ernal corrosion protection DIN EN 806 2 External corrosion protection DIN 1988 200 External corrosion protection DKI Informationsdruck i 160 Scope Notice Regulations applicable in Ger many Leakage tes...

Page 8: ...model is also suitable for the following media amongst others n Drinking water without limitations acc to the applicable directives see Regulations from section Media on page 6 n maximum chloride con...

Page 9: ...reventer for DN 50 n drainage testing plugs G upstream and downstream from the backflow preventer for DN 65 80 100 n valve and spindle seal made of EPDM maintenance free The model is fitted with a bac...

Page 10: ...t complies with the nom inal width of the pipeline The backflow preventer must be fitted with testing equipment In many countries standards and technical guidelines stipulate the use of backflow preve...

Page 11: ...n on page 7 Easytop fittings made of gunmetal silicon bronze are suit able for all types of potable water The chloride concentration in the medium must not exceed a maximum value of 250 mg l This chlo...

Page 12: ...Fig 3 Model 2259 7 XL mounting set Fig 4 Model 2259 9 XL seal Product information Easytop XL CRV slanted seat valve combined free flow valve with backflow preventer with flange connection 12 from 14...

Page 13: ...tion so that the fitting is easily accessible and simple to operate For information refer to the instructions for use of the Profipress Profipress XL Sanpress Sanpress XL and Sanpress Inox Sanpress In...

Page 14: ...regulations for the operation and maintenance of drinking water installations see Regulations from section Mainte nance on page 8 Viega recommends actuating the fitting regularly and checking its func...

Reviews: