Viega 8625.1 Instructions For Use Manual Download Page 3

1

About these instructions for use

Trade mark rights exist for this document; for further information, go to

viega.com/legal

.

1.1

Target groups

The information in this instruction manual is directed at the following

groups of people:

n

Heating and sanitary professionals and trained personnel

n

Operators

n

Consumers

Individuals without the abovementioned training or qualification are not

permitted to mount, install and, if required, maintain this product. This

restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with

the general rules of engineering and the Viega instructions for use.

1.2

Labelling of notes

Warning and advisory texts are set aside from the remainder of the text

and are labelled with the relevant pictographs.

DANGER!

 

This symbol warns of possible life-threatening injury.

WARNING!

 

This symbol warns of possible serious injury.

CAUTION!

 

This symbol warns of possible injury.

NOTICE!

 

This symbol warns of possible damage to property.

This symbol gives additional information and hints.

About these instructions for use

WC flush plate for Prevista Visign for More 205 sensitive

3

Summary of Contents for 8625.1

Page 1: ...Instructions for Use WC flush plate for Prevista Visign for More 205 sensitive for all Prevista concealed cisterns Model Year built from 8625 1 05 2019 INT...

Page 2: ...8 2 3 4 Operating mode 8 2 3 5 System expansions 9 2 4 Accessories 10 3 Handling 12 3 1 Assembly information 12 3 1 1 Mounting conditions 12 3 1 2 Required material and tools 12 3 2 Assembly 13 3 2 1...

Page 3: ...tend to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes...

Page 4: ...g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The relevant national la...

Page 5: ...roduct replaced by qualified personnel n This product is not intended for use by persons including children with restricted physical sensory or mental aptitude or lack of experi ence and or knowledge...

Page 6: ...Symbol Description Direct current Protection class III The marked product must not be disposed of as household waste Product information WC flush plate for Prevista Visign for More 205 sensitive 6...

Page 7: ...mall flush volume approx 2 3 4 litres n Large flush volume approx 3 5 4 5 6 7 5 litres For the setting of the flush see Chapter 3 3 1 Setting the flush on page 22 If the external sensor e g a remote b...

Page 8: ...ista 1 Power pack 2 Electronic drive unit 3 WC flush plate for Prevista 2 3 4 Operating mode Flushes from Prevista concealed cisterns are actuated contact free via the flush plate The sensor range is...

Page 9: ...on is deactivated at the factory When a person enters the detection zone closer than 2 m the flush plate lights up 2 3 5 System expansions The system s range of functions can be expanded through the c...

Page 10: ...ion cable model 8352 690 2 metre cable for the extension of the power supply Use a maximum of two extension cables with the power pack 4 75 meter total length Connection cable model 8570 55 3 meter ca...

Page 11: ...580 49 For connection of a radio receiver WC remote actuation models 8640 1 and 8641 1 For electronic remote actuation at Prevista concealed cisterns Product information WC flush plate for Prevista Vi...

Page 12: ...it their connec tion cables or empty pipes must be laid in the cistern before tiling is begun see Chapter 2 3 5 System expansions on page 9 3 1 2 Required material and tools The following material is...

Page 13: ...wall n The pre wall is tiled Remove the shaft cover Cut into the corners of the revision shaft Fold the sides of the revision shaft outwards up to the tile level and snap them off 3 2 2 Mounting the...

Page 14: ...e cover plate Close the corner valve Loosen the flexible hose at the filling valve Open the corner valve for a few seconds to flush the pipe Handling WC flush plate for Prevista Visign for More 205 se...

Page 15: ...filling valve Re open the corner valve INFO Check the corner valve and the filling valve for leak tightness Set the desired flush volume see Chapter 3 3 1 Set ting the flush on page 22 Handling WC fl...

Page 16: ...cover plate into the cistern Turn the cover plate lock by 90 in a clockwise direction Put on the installation frame Insert the retaining bolts Handling WC flush plate for Prevista Visign for More 205...

Page 17: ...o fix the retaining bolts turn safety rings in a clockwise direction If you are not sure which cistern is installed identify it by means of the following dimensions n 3H concealed cistern n concealed...

Page 18: ...e for the actuating rod INFO Cistern 3H and 3L If necessary cut the actuating rod to length n 0 75 50 mm n 1 50 25 mm n 2 25 10 mm INFO Cistern 3F If necessary cut the actuating rod to length n 1 75 5...

Page 19: ...essary cut the actuating rod to length n 0 60 45 mm n 1 45 25 mm n 2 25 10 mm Push the actuating rod through the left opening of the installation frame as far as it will go Align the actuating rod Tur...

Page 20: ...alibrated During calibration the flush plate is functionless for 60 seconds If required additional external sensors can be connected to the drive unit See Chapter 3 2 3 Connecting external sensors on...

Page 21: ...at least 350 ms available n Connection cable available Connect the contact to actuate the small flush volume between the green 1 and yellow cable 3 Connect the contact to actuate the large flush volu...

Page 22: ...me B Interval of the Viega Hygiene function C Setting the flush volume of the Viega Hygiene function 0 DIP switch position OFF 1 DIP switch position ON The assignment of the DIP switches n Switches 1...

Page 23: ...ing 6 3 0 0 0 0 Program 1 3 5 2 0 0 0 1 Program 2 4 5 2 0 0 1 0 Program 3 6 2 0 0 1 1 Program 4 7 5 2 0 1 0 0 Program 5 3 5 3 0 1 0 1 Program 6 4 5 3 0 1 1 0 Program 7 7 5 3 0 1 1 1 Program 8 4 5 4 1...

Page 24: ...he plugs of control and flush plate have not been connected Establish the plug connection Chapter 3 2 2 Mounting the flush plate on page 13 The WC flush runs through The seal at the filling valve is d...

Page 25: ...ultaneously for 5 s before the detection areas 3 6 Disposal Separate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accordance with valid national...

Page 26: ...Viega Technology GmbH Co KG service technik viega de viega com INT 2020 07 VPN200193...