![Viega 8625.1 Instructions For Use Manual Download Page 19](http://html1.mh-extra.com/html/viega/8625-1/8625-1_instructions-for-use-manual_1016601019.webp)
INFO!
For installation from above into concealed cistern 3L.
▶
Determine the distance for the actuating rod.
▶
If necessary, cut the actuating rod to length.
n
0: 60–45 mm
n
1: 45–25 mm
n
2: 25–10 mm
▶
Push the actuating rod through the left opening of the installation
frame as far as it will go.
▶
Align the actuating rod.
▶
Turn the actuating rod clockwise by 90°.
9
d
Handling
WC flush plate for Prevista Visign for More 205 sensitive