2.3.3
Connection diagram
/
-
̖7_
7
EBUB
EBUB
Fig. 2: Connection diagram, power pack, WC flush plate for Prevista
1 Power pack
2 Control with motor
3 WC flush plate for Prevista
2.3.4
Operating mode
Flushes from Prevista concealed cisterns are actuated electronically via
the flush plate.
Optionally, a large or small flush volume can be flushed.
Stagnation can lead to the build up of germs (e.g. legionella) in potable
water pipelines. It is important to rinse the pipeline regularly to prevent
the build up of bacteria. The Viega function was developed for
this reason.
Flushes are actuated in a time-controlled manner with the Viega
function. Interval and flush volume will be set as required and
saved by the control. All settings remain saved during a power cut.
The function can be disabled.
Viega function
Product information
WC flush plate for Prevista Visign for More 204 electronic
9 from 25