3.3
Errors, faults and remedy
Error
Cause
Remedy
The urinal does not flush.
The shut-off valve closed.
Open the shut-off valve.
The cartridge valve dirty or dam‐
aged.
Clean the cartridge valve, if neces‐
sary replace it.
The flush is too weak.
The shut-off valve is not open far
enough.
Open the shut-off valve.
The cartridge valve dirty or dam‐
aged.
Clean the cartridge valve, if neces‐
sary replace it.
The urinal flush runs through.
The cartridge valve dirty or dam‐
aged.
Clean the cartridge valve, if neces‐
sary replace it.
3.4
Care and maintenance
3.4.1
Care tips
Use normal soap or a mild cleaning agent for regular care and preven‐
tion of lime scale on the flush plate. Under no circumstances should
scouring agent or scratching objects be used.
Strong stains can be removed using typical household cleaner. Rinse
the detergent thoroughly with clear water after the prescribed exposure
time. There should be no residue on the components.
3.4.2
Cleaning cartridge valve
Clean the cartridge valve if necessary. Proceed as follows:
▶
Remove the flush plate from the installation frame.
Handling