3 Handling
3.1
Transport and storage
Observe the following with transport and storage:
n
Avoid heavy blows and vibrations.
n
Store components in a clean and dry place.
n
Do not remove the components from the packaging until immedi-
ately before use.
NOTICE!
Replace defective components, do not repair.
3.2
Preconditions for installation
A power pack provides 24 V operating voltage to the basic unit. For
operation, the customer must provide a 230 V socket in direct vicinity of
the manifold.
3.3
Assembly
3.3.1
Assembly sequence
To assemble the components, proceed as follows:
n
Mount the room thermostats.
n
Mount the actuators on the manifold.
n
Mount the basic unit.
n
Mount the power pack.
n
Connect the cables of the room thermostat and the actuators with
the basic unit.
n
Establish the power supply / commission.
Handling
Basic unit 24 V
with pump module
10 from 17