  c) calculated components             d) the result of balancing ch. A      e) the result of balancing ch. B

 

 

7.4.3

 

Grinding wheels balancing 

Main menu 

 Measuring 

 Balancing 

 Grinding wheels 

This  option  is  used  for  dynamic  balancing  of  two  rotating  wheels  on  short  shafts  of  rotating 
machines.

  For  correct  function,  the  speed  sensor  must  be  connected.  Further,  it  is 

necessary  to  label  the  zero  degree  on  the  circular  (angular)  scale  of  the  rotating  wheel 
with a reflective band. From this reference position (0°), the following runs are calculated. 
After executing the process, screen with selection of previously saved machine coefficient 
appears. You can choose the coefficients from database (balancing without the test run) 
or do the measuring without choosing the coefficient from database (balancing with the 
test run). After initiation the wizard is displayed, and asks to enter the machine rotation 
direction and then to enter the position of the accelerometer towards the  speed sensor. 
The position is then noted in the balancing results. 

3 weights of the same weight should be present on the grinding wheel, which are spaced apart 
by 120 ° to position 0 °, 120 ° and 240 °, and therefore their influence on the balancing is 
completely zeroed. Weights are placed permanently, and cannot be removed. All three weights 
are used for the calculation. 

First  run:

  Balancing  grinding  wheel  operates  only  with  one  channel,  which  is  set  by 

default to  channel  A. Click the forward arrow to  start  vibration analysis of rotating blade. To 
support  the  analysis,  the  flywheel  must  spin  at  a  steady  state.  Until  this  stage  is  reached,  the 
screen is greyed out and the arrow for proceeding is inactive. After the analysis, the vibration 
velocity  will  be  shown,  see  Figure  19a. 

Vibration velocity value is relative to the maximal 

amplitude of one dominant component in the spectrum – in this sense it is the revolution 
frequency.  

Test run:

 for determining the place of displacement of various weights, a run must be 

performed with weight shifted to a certain position, which together with the weight must be 

Summary of Contents for Vibrodiag

Page 1: ...www viditech eu rev 1 7 sales viditech cz www ViDiTech eu Vibrodiag FW 0 04 41 and higher...

Page 2: ...MENU 8 5 1 INSTRUMENT SETUP 9 5 2 SENSOR SETUP 10 5 3 LIMITS SETUP 10 6 DATABASE ROUTES 11 6 1 MEASURING PLACES 11 6 2 ROUTES 11 7 MEASURING 13 7 1 ROUTE MEASURING 13 7 2 ANALYSIS 14 7 2 1 Velocity an...

Page 3: ...to 60g Range of measured velocities up to 200 m s 1 using provided sensors RMS vibration measurement according to ISO 2373 Balancing wizard Threshold recorder Periodical recorder ICP acceleration sens...

Page 4: ...ch TFT Display diagonal 3 4 Memory card type SD PCconnection USB 2 0 2 2 Accuracy Total vibrations at80 Hz 2 1 digit within range 1 5 000 Hz 10 1digit at limit frequencies 10 20 1digit Frequencycharac...

Page 5: ...nsor sensitivity 100 mV g 20 Range of measured accelerations 60 g Protection IP67 Chassis material stainless steel Dimensions 25x66 mm diameter height Weight 125 6 g Connector M12 Attachment outer thr...

Page 6: ...channel A 5 Socket for ICP sensor channel B 6 Socket for revolution sensor 7 Socket for supply connector 8 Socket for USB connector 9 SD card slot 10 Power supply adapter 15 V 1 6 A 11 ICP sensor cabl...

Page 7: ...ts the instrument stabilizes the filters for only 2 s 3 1 2 ICP sensors ICP sensors are connected with the unit using shielded cables with colour distinguished connectors for each channel The only and...

Page 8: ...m Analysis Balancing Recorder VibroGuide Order 1 Hz 1 kHz velocity 500Hz 5kHz acceleration Custom Saved data Run up coast down Run up Coast down Saved data Single plane Dual plane N planes Saved data...

Page 9: ...equently it is possible to save individual measurements which point to the selected places routes Item Measuring contains all options of measuring allowed by the purchased licences see Setup i VibroGu...

Page 10: ...erm instrument non use there is a danger of set date and time loss After power resupply in form of charged battery or connected charger random date and time are set and is therefore necessary to updat...

Page 11: ...imits setup Main menu Setup Limits Limits are used to advise of detected increased values of vibration velocity on the diagnosed object These increased vibrations refer to the current machine state Li...

Page 12: ...by place definition of Machine using icon and place parameters setup using icon with switching screens left right see fig 10 Here it is possible to set parameters of channel A and B and predefined op...

Page 13: ...sales viditech cz 12 Fig 9 a Factory definition b Machine definition c Machine information Fig 10 a Place definition b Place setup c Place setup Fig 11 a Route definition b Adding place to route c Di...

Page 14: ...performed by tapping on the box next to the relevant channel Bar graphs change colour according to the level of signal in reference to the set limits L1 L2 If RMS velocity exceeds threshold L1 bar gra...

Page 15: ...requency and amplitude see fig 14b After specifying the relevant value in the table row the setting will change back to graph and mark the selected point using a cursor Values in the table and graph a...

Page 16: ...sales viditech cz 15 Fig 13 a Analysis selection b Channel selection c Running analysis Fig 14 a Analysis display b Table of values c Optional analysis Fig 15 a Saved analyses b Saved analysis c Addi...

Page 17: ...ther with the current vibration velocity values are displayed in the bottom part of the screen After revolutions set in final state run up to maximum coast down to minimum it is necessary to end the r...

Page 18: ...Personnel without appropriate practice should not conduct these measurements 7 4 1 Balancing in single plane Main menu Measuring Balancing Single plane This option is used for balancing thin rotating...

Page 19: ...ancing weights it is necessary to remove the test weight A control may be done by performing a new balancing It is possible to return by one step back leave and save result in the balancing process Fi...

Page 20: ...s sense it is the revolution frequency Test Run Sizing counterweight must be performed with a running test weight Test weights are attached to balancing wheels the weight and the position must be ente...

Page 21: ...er the position of the accelerometer towards the speed sensor The position is then noted in the balancing results 3 weights of the same weight should be present on the grinding wheel which are spaced...

Page 22: ...ocess can return one step back leave save the result and store parameters Fig 19 a first run b the calculation of weights c the result of balancing 7 4 4 Displaying saved balancing Main menu Measure B...

Page 23: ...VIBRODIAG www viditech eu sales viditech cz 22 Fig 18 a Saved data b Informative data c Measured results...

Page 24: ...hreshold absolutely in mm s or relatively by entering percent of range The numerical value of threshold is entered by tapping on the box marked Threshold It is possible to record Velocity analysis Acc...

Page 25: ...02 30 and for Vibration 00 00 02 fig 21a After analysis initiation the following are displayed time till end of one period and saving of first and subsequently the following record If the symbol is in...

Page 26: ...nnel sensing are preset Maximal number of analyses that can be loaded for the threshold recorder is 10 only 5 of them are displayed in the graph Information about the current selected analysis are sho...

Page 27: ...AG www viditech eu sales viditech cz 26 Fig 22 a Saved data from rec b Threshold rec vibrations c Threshold rec analyses Fig 23 a Adding another analysis b Periodical rec vibrations c Periodical rec a...

Reviews: