Installation
Vidikron PlasmaView VHD Installation/Operation Manual
23
PRE
L
IMINAR
Y
RS-232 Connection:
Connect the RS-232 output from the VHD Controller to the
SERIAL
input on the PlasmaView VHD. Use a standard, modular telephone cable with RJ11 plugs at
both ends. On the PlasmaView VHD end, use the provided RJ11-to-DB9 adapter. This adapter
is wired as shown in Figure 3-5.
Figure 3-5. RS-232 Connection from the VHD Controller to the PlasmaView VHD
3
4
2, 5
XMT DATA
RC
V
DATA
REQUEST TO SEND
SIG GND
3
2
8
7
5
RC
V
DATA
XMT DATA
CLEAR TO SEND
NO CONNECTION
1, 6
1, 9
SIG GND
To/From
VHD
Controller
PlasmaView
RJ-11 Male
DB-9 Female
1 5
6 9
SERIAL