background image

66251980 - V1.2 - 31/07/21

- 12 -

Serie Kristallo

Art. KRV72 - KRV74 - Istruzioni di installazione

IMPOSTAZIONE INDIRIZZO VIDEOCITOFONO SW1

L’indirizzo del videocitofono è codificato in binario tramite il dip-switch ad 8 vie situato al suo interno. Ogni switch corrisponde ad 
un bit che può essere a 0 (OFF) o 1 (ON), a ciascun bit corrisponde un peso decimale in base alla posizione: per impostare l’indirizzo 
desiderato, mettere ad ON (1) gli switch la cui somma dei pesi corrisponde al valore dell’indirizzo. Ad esempio, per impostare l’indi-
rizzo 37, mettere ad ON gli switch 1, 3 e 6 (1+4+32=37).

SWITCH

PESO DECIMALE

INDIRIZZO

8

7

6

5

4

3

2

1

128

64

32

16

8

4

2

1

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

0

0

0

0

0

0

0

1

1

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

0

0

0

0

0

0

1

0

2

OFF

OFF

OFF

OFF

OFF

OFF

ON

ON

0

0

0

0

0

0

1

1

3

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

0

0

0

0

0

1

0

0

4

OFF

OFF

ON

OFF

OFF

ON

OFF

ON

0

0

1

0

0

1

0

1

37

ON

OFF

ON

ON

OFF

ON

OFF

OFF

1

0

1

1

0

1

0

0

180

MODO VIDEO SW2

La modalità video viene impostata 
tramite il dip-switch a 4 vie accessibile 
dalla parte posteriore del blocco 
superiore del videocitofono.

Gli switch 3 e 4 servono ad adattare 
l’impedenza del segnale video; in 
caso di più videocitofoni collegati 
in parallelo, devono essere 
impostati entrambi ad OFF per tutti i 
videocitofoni ad eccezione dell’ultimo 
in ordine di collegamento

MODO VIDEO 

Switch 1,2

Modo

ON 

1 2

3 4

Coassiale

ON 

1 2

3 4

Bilanciato

TERMINAZIONE VIDEO 75 OHM

Switch 3,4

Terminazione

ON 

1 2

3 4

Attiva

ON 

1 2

3 4

Disattiva

SEGNALI MORSETTIERA DI CONNESSIONE

DOL

In12Vdc per LED “door open”

SB

Uscita open collector pulsante di servizio (tipo at-
tivo basso). Con il monitor acceso, si attiva tenen-
do premuto il pulsante 

 fino a che no si abilita il 

servizio. L’uscita resta attiva per circa 2 secondi. 

50mA 24Vdc max.

AL

Ingresso attivo basso per segnale di allarme. Quando 
attivo, il sistema invia l’allarme al centralino di port-
ineria se presente e attiva l’Art. 512DR se presente ed 
opportunamente configurato.

LB

Ingresso attivo basso per chiamata di piano “Local Bell”.

L

Ingresso linea dati BUS.

Ingresso massa linea BUS.

12Vin

In12Vdc di alimentazione in stand-by.

12Vout

Uscita stabil12Vdc

GND

Ingresso massa di alimentazione / massa segnale vi-
deo coassiale

V2/V

Sincronia V2 segnale video bilanciato (modo seg. 
video bil.) Segnale video composito (modo segnale 
video coassiale)

V1

Sincronia V1 segnale video bilanciato

+20

Ingresso di aliment20Vdc

+VD

Uscita 12Vdc per alimentazione distributore video 
Art. 894/Art. 894N

NOTE

Quando si fa il ponte tra 12Vin e 12Vout, un Art.893N1 addizio-
nale è necessario ogni 50 videocitofoni presenti nel sistema.

SPECIFICHE TECNICHE

Formato e montaggio:

Serie Kristallo 3,5”
Superficie (Art. KRV72)
Incasso (Art. KRV74)

Pulsanti touch sensitive 
retroilluminati:

8

Programmazioni:

Tramite pulsanti e dip-switch

Regolazioni:

Volume fonia
Luminosità
Saturazione

Assorbimenti:

Stand-by:

6 mA (on 12Vin)

In funzione: 200 mA
Picco:

250 mA

Tensione di lavoro:

17-20Vdc

Temperatura di lavoro:

-20 +60 °C

Art. KRV72-KRV74

 Videocitofono vivavoce 3,5”

Summary of Contents for VX2200

Page 1: ...ight buttons Adjustments volume speech picture brightness and hue LEGEND A Microphone B Display C LED s and touch buttons D Loudspeaker D Handset E Connection terminals F 4 Way dip switch bank G 8 Way...

Page 2: ...ng an incoming call press this button to reject the call The visitor doesn t receive any warning of the call rejected DURING A CONVERSATION BUTTON OPERATION End conversation Press to end a call Activa...

Page 3: ...he unit emits a double beep that confirms the new setting is properly stored 4 After 5 seconds without any user action the unit returns to stand by mode Available melodies 9 MELODY VOLUME 1 Press and...

Page 4: ...f your choice be tween or that you want to associate to the address just set 6 The unit now emits slow beeps and and LED s flash slow reset the previous annotated dip switch setting Button programming...

Page 5: ...tion ON 1 2 3 4 Enabled ON 1 2 3 4 Disabled CONNECTION TERMINALS SIGNALS DOL 12Vdc input to supply door open LED SB Open collector output active low for service call button When the monitor is switche...

Page 6: ...6 Kristallo Series Art KRV72 KRV74 Installation instructions Kristallo Series 3 5 flush and surface videomonitor wall mounting instructions Fig 4 135cm 135cm Fig 1 Fig 1a Fig 2a Fig 4 Fig 4a Fig 4b Fi...

Page 7: ...gainst the videophone by inserting the hooks in the corresponding openings and hook the plate by pushing it down as shown in Fig 4 5 Test the system for correct operation SURFACE MOUNT KRISTALLO VIDEO...

Page 8: ...agine LEGENDA A Microfono B Display C LED e pulsanti touch D Altoparlante D Cornetta E Morsettiera di connessione F Dip switch a 8 vie G Dip switch a 4 vie FUNZIONAMENTO DURANTE LO STAND BY PULSANTE F...

Page 9: ...ore non riceve alcun avviso della chiamata rifiutata DURANTE LA CONVERSAZIONE PULSANTE FUNZIONE Chiusura conversazione Premere per chiudere la conversazione Attivare la modalit Push to Talk Premere e...

Page 10: ...onferma della memorizzazione della nuova impostazione 4 Dopo 5 secondi senza alcuna azione da parte dell utente l unit torna in stand by Melodie disponibili 9 VOLUME SUONERIA 1 Premereetenerepremutoil...

Page 11: ...ra asso ciare all indirizzo appena impostato 6 L unit emette ora bip lenti ed i LED e lampeggiano lentamente reimposta re la precedente impostazione annotata del dip switch La programmazione dei pulsa...

Page 12: ...75OHM Switch 3 4 Terminazione ON 1 2 3 4 Attiva ON 1 2 3 4 Disattiva SEGNALI MORSETTIERA DI CONNESSIONE DOL Ingresso 12Vdc per LED door open SB Uscita open collector pulsante di servizio tipo at tivo...

Page 13: ...rie Kristallo Art KRV72 KRV74 Istruzioni di installazione SerieKristalloIstruzioni di montaggio a parete videocitofoni 3 5 da incasso e da superficie 135cm 135cm Fig 1 Fig 1a Fig 2a Fig 4 Fig 4a Fig 4...

Page 14: ...nelle rispettive fessure quindi fissare la stessa spingendola verso il basso come mostrato in Fig 4 5 Procedere al collaudo del sistema VIDEOCITOFONI KRISTALLO DA SUPERFICIE 1 Come mostrato in Fig 1a...

Page 15: ...66251980 V1 2 31 07 21 15...

Page 16: ...66251980 V1 2 31 07 21 16...

Page 17: ...66251980 V1 2 31 07 21 17...

Page 18: ...66251980 V1 2 31 07 21 18...

Page 19: ...ion et vite les ventuels effets n gatifs sur l environnement et la sant humaine en raison de la pr sence possible de substances dangereuses dans ceux ci ELIMINACI N De conformidad con el Decreto legis...

Page 20: ...om nl info videxintercom nl TheproductisCEmarkeddemonstratingitsconformityandisfordistributionwith in all member states of the EU with no restrictions This product follows the provi sionsoftheEuropean...

Reviews: