(1) Power input: The total power provided by the product  for PoE supply, i.e.  the 
power provided by built-in 54V power, has been set up when it leaves the factory, 
please do not modify it. If users modified the  power supply,  please correct this 
setting. If the setting value is larger than the  actual power of the built-in power 
supply, there will be a damage of built-in power. If the setting value is smaller than 
the actual power of built-in power supply, built-in power supply could not be fully 
allocated out. 

(2) Allowing maximum overload: built-in power allows overload value setting range 
is 0%-10%, default is 5%.  If actual power is too large that cause built-in power 
overload exceeding setting value, the system will turn off power supply of low 
priority ports. For example:when input power is 360w, maximum overload is 5%. 
when actual output power exceeds 360*(1+5%)=378w , the system overloads.

(3) Power Reservation: power reservation could not be contributed, but be used for 
PoE equipment consumption due to load changes. Default power reservation is 
15% of total power. The higher the value, the slower the risk of system overload, the 
power to be contributed decreases,  and the number of PoE equipments to be 
connected decreases; on the contrary , the more the  number of  PoE equipments to 
be connected, the higher risk of system overload.  

(4) Operation instructions: after setting the value, press <OK> button. Setting 
succeeds  when the following  window pops out.

3.3.2.9 Power Status

 

Power status page diagram 

The input power, allowing maximum overload and reserved power have 

been set up before the product leaves the factory. User is allowed to modif 

it, prudently.

3.3.2.8 PoE Setting

 

Diagram of PoE setting page

3 3 2 5 Restore IP Address and Login Password

. . .

 

Start the product, unplug the network cable  of console port, then press init 

key(3

5 seconds), till the RJ45 LED light of console port flash once, the IP 

address and login password  will be restored to  the initial setting.  

 

3 3 2 6 Equipment Information

. . .

Click menu bar [equipment information] on Web page , then three product 

information of [IP address], [MAC address] and [software version] will be popped 

out for user checking. After  review, click <Exit> to log out checking status. 

  

Equipment information diagram

3 3 2 7 Exit

. . .

Click

 

main

 

menu

 [

Exit

to

 

return

 

to

 

login

 

page

.

  

Diagram of restore IP address, login password

 

17

18

Instruction

PoE Output Ports

PoE

 

Web 

Management  

Port

PoE

 

Output 

LED

Reset

PoE Output 
Percentage 

LED

Summary of Contents for JAR-SW16-P300

Page 1: ...16 24 Ports PoE switch User Manual ...

Page 2: ... 1 1 2 Board Diagram 1 3 Specification 2 1 4 Product Feature 3 2 Installation 4 2 1 Shipping List 4 2 2 Installation Precautions 4 2 3 Installation Way 6 2 3 1 Rack Installation 6 2 3 2 Workbench Installation 7 2 4 Cable Connection 8 2 4 1 Device Connection 8 2 4 2 Configuration Cable Connection 2 4 3 Power Line Connection 3 PoE Web Management Page 3 1 Preparation Work 3 2 Set up Network Connectio...

Page 3: ...PoE Web Management Port PoE Output LED Reset PoE Output Percentage LED PoE Output Ports Reset PoE Web Management Port PoE Output LED Uplink Gigabit Ports PoE Output Percentage LED 24 Ports PoE switch AC100 240V Grounding Terminal 16 Ports PoE switch Provide 16 24x 100Mbps downlink PoE Ethernet ports 2x gigabit uplink Ethernet ports and 1x gigabit Fiber port Downlink Ethernet ports support PoE each...

Page 4: ...ng Terminal PoE Power Power Input Mains on load 100 240VAC 50 60Hz PoE Power Supply End span 1 2 3 6 IEEE802 3 af at PoE Max Power Output 250W 370W 340W if 110V AC input Single Port Power Output Voltage Single Port PoE Power Output 30W Voltage 54VDC PoE Web Management PoE Management Via Web Default IP Address 192 168 1 200 to check on off and adjust each port PoE output Reset Button PoE Web Reset ...

Page 5: ...ch may be affected by external interference outside the system through the ways of radiation and conduction Please pay attention to the followings AC power supply is TN system so it is necessary to use single phase power socket PE which can protect ground wire so that the filter circuit can effectively filter out the power grid disturbances The switch should work far away from high power radio tra...

Page 6: ...port switch when install the switch to the rack 2 3 2 Workbench Installation You can put this product on clean stable grounded workbench The installation procedure is as below 1 Put the device upside down carefully clean the grooves on the chassis backplane with soft cloth to make sure there is no oil or dust in it 2 Remove the stickers on the foot pad paste the foot pad in backplane groove 3 Put ...

Page 7: ...ourself Operation steps take Windows XP as sample 1 Click start to enter the start menu select control panel Double click network connection icon double click the local connection icon pop out local connection status window Make sure the management PC has already been installed with Ethernet adapter Use network cable to connect the console port with management PC Instruction 2 Click property butto...

Page 8: ...ernet option enter Internet option window 3 3 Operating Guidance of Web 3 3 1 Start and Login This product web default IP address 192 168 1 200 subnet mask 255 255 255 0 administrator account admin password admin After installing the equipment correctly and setting up the computer open the browser input the injector default address in the browser address bar then press the Enter key the user login...

Page 9: ... and wait for 10 seconds till product IP address is successfully changed 13 14 After inputting the correct user name and password click Login and the browser will show the product Web management page as the picture below Please follow the steps to check if the injector is installed correctly 1 Whether the physical connection of the equipment is correct The other end of the network line that is con...

Page 10: ...hat the computer IP address and the product IP address must be in the same network segment and the settings of subnet mask and gateway must be correct 2 When changing product IP address please ensure the power supply to avoid abnormal problems 3 What to do if you forget the IP address of the product Please refer to 3 3 2 5 restore the initial setting 3 3 2 3 Change Password Login password the prod...

Page 11: ...e power to be contributed decreases and the number of PoE equipments to be connected decreases on the contrary the more the number of PoE equipments to be connected the higher risk of system overload 4 Operation instructions after setting the value press OK button Setting succeeds when the following window pops out 3 3 2 9 Power Status Power status page diagram The input power allowing maximum ove...

Page 12: ... port and popup dialog box Take port 1 as an example press OK popup setup is successful When setting succeeds corresponding button becomes 1 Actual output total actual output power 2 Surplus the power to be used for redistribute Surplus input actual output reservation please noted that the product distributes power according to power level of detected PoE powered device when connecting a new PoE p...

Page 13: ...r setting parameters press OK button of the corresponding port then popup setting success when operation finishes Setting all the port parameters press port control and status actual output power W button then popup dialog box as shown below Press OK when all the setting finishes popup setup is successful Setting unified allowed maximum output power as shown below After selecting the check box all...

Reviews: