Instruc
tion manual - English - EN
13
MNVCWASNX_1915_EN
9 Cleaning
Frequency will depend on the type of
environment in which the product is used.
The device should be cleaned using a damp cloth;
compressed air must not be used.
10 Information on disposal
and recycling
The European Directive 2012/19/EU on Waste
Electrical and Electronic Equipment (WEEE) mandates
that these devices should not be disposed of in the
normal flow of municipal solid waste, but they should
be collected separately in order to optimize the
recovery stream and recycling of the materials that
they contain and to reduce the impact on human
health and the environment due to the presence of
potentially hazardous substances.
The symbol of the crossed out bin is marked
on all products to remember this.
The waste may be delivered to appropriate collection
centers, or may be delivered free of charge to the
distributor where you purchased the equipment at
the time of purchase of a new equivalent or without
obligation to a new purchase for equipment with size
smaller than 25cm (9.8in).
For more information on proper disposal of these
devices, you can contact the responsible public
service.
11 Technical data
11.1 General
Enclosure made of stainless steel AISI 316L
Delivery pipe supplied
• Length: 20m (66ft)
11.2 Mechanical
Pressure: 4bar max
Delivery head: 20m (66ft)
Material (delivery pipe): Antistatic plastic
Dimensions (WxHxL): 429x697x255mm
(16.9x27.4x10in)
Unit weight: 18kg (40lb)
Water tank capacity: 10l (2.6gal)
11.3 Electrical
Supply voltage/Current consumption
• 230Vac, 0.07A, 50/60Hz
• 120Vac, 0.13A, 50/60Hz
• 24Vac, 0.7A, 50/60Hz
11.4 Environment
For installation indoors and outdoors
Operating temperature of solenoid valve: from -20°C
(-4°F) to +60°C (140°F)
Operating temperature of device: depending on the
solidification temperature of the liquid
11.5 Certifications
Electrical safety (CE): EN60950-1
Electromagnetic compatibility (CE): EN61000-6-2,
EN61000-6-3
Outdoor installation (CE): EN60950-22
IP protection degree (EN60529):
• IP65 (solenoid valve only, enclosure not rated)
EAC certification
Summary of Contents for WASNX
Page 2: ......
Page 59: ...RU WASNX...
Page 61: ...RU 3 MNVCWASNX_1915_RU 1 1 1 INFO 2 3 15A max 3mm 1...
Page 63: ...RU 5 MNVCWASNX_1915_RU VIDEOTEC 4 4 1 WASNX WASNX 10 4 2 2...
Page 64: ...RU 6 MNVCWASNX_1915_RU 5 5 1 5 2 5 3 5 4 5 4 1 3 01 02 02 01 4 5 4 2 5...
Page 65: ...RU 7 MNVCWASNX_1915_RU 5 4 3 6 7 mm mm M16 16 5 5 9 M20 20 5 8 12 1 5 4 4 8 9 10...
Page 73: ......