7  Vk602b.doc 

1.4  Connecting to more than one Digital Recorder 

Digital Recorders can be daisy-chained as illustrated in the diagram below. This configuration allows one or 
more keyboards to control multiple Digital Recorders. It also ensures that the clocks of the Digital Recorders 
are kept exactly in step (within a second). If the time and date needs adjusting, adjust clock of the “Master”. 
The “Slave” will be updated automatically (every minute). 

 

DIGITAL RECORDER (CLOCK MASTER)

DIGITAL RECORDER (CLOCK SLAVE)

Connect to

“IN+” and “IN-”

Connect to

“IN+” and “IN-”

of all other slave VDMs

TWISTED-PAIR

CABLE

T25A

TERMINAL PCB

RS485 TERMINATION = ON

CAT5 CABLE

to 

KEYBOARD(S)

Connect to

“OP+” and “OP-”

The last slave VDM should have its RS485 termination ON,

other slaves should have RS485 termination OFF

 

Note: 

RS485 termination may be switched ON either using the switch on the T25A PCB or using the miniature 
slide switch on the rear of the VDM. Do not turn both termination switches ON. 

Intelligent Security and Fire Ltd

Summary of Contents for VK-1

Page 1: ...th 16 Cameras and 2 Monitors Document Ref Vk602b doc Date 07 07 2003 Videoswitch Telephone 01252 851510 Units 15 16 Fax 01252 851296 Redfields Industrial Park Email sales videoswitch co uk Redfields L...

Page 2: ...VK 1 Remote Keyboard User Manual 23 09 2004 11 09 Videoswitch Page 1 Vk602b doc I n t e l l i g e n t S e c u r i t y a n d F i r e L t d...

Page 3: ...to more than one Digital Recorder 7 2 Front Panel Controls 8 2 1 Configuring VDM Digital Recorder 8 2 2 Full Control 8 2 3 Spot Monitor Only Control 8 2 4 Addressing more than one VDM Digital Recorder...

Page 4: ...ommended that a coax video cable be run directly to the monitor Additionally the 12V power supply provided should be plugged into the VK 1 as voltage loss along the twisted pair cable may be too great...

Page 5: ...d pair you will need an adapter PCB order code T25A and a video balun order code VX 2 The above configuration is satisfactory for cable runs up to 200 metres Above this distance the video quality will...

Page 6: ...11 09 Videoswitch Page 5 Vk602b doc 1 3 Connecting more than one keyboard Another keyboard can simply be added by connecting it to the Loop In RJ45 connector on the master VK 1 keyboard I n t e l l i...

Page 7: ...OR 75 Ohms IN 75 Ohms IN ON VK 1 KEYBOARD BNC CABLE VK 1 KEYBOARD BNC CABLE Note that the first monitor should be un terminated set to high impedance and the second monitor should be terminated set to...

Page 8: ...of the Master The Slave will be updated automatically every minute DIGITAL RECORDER CLOCK MASTER DIGITAL RECORDER CLOCK SLAVE Connect to IN and IN Connect to IN and IN of all other slave VDMs TWISTED...

Page 9: ...unction as the keys build into the VDM recorder itself Refer to the VDM operating manual for details 2 3 Spot Monitor Only Control The keyboard may be configured to provide control of the spot monitor...

Page 10: ...n Description 1 RS485 Data A Output 2 RS485 Data B Output 4 12V Power Input 5 Ground Screen 7 Video 8 Video 3 3 Loop In RJ45 Pin Description 1 RS485 Data A Input 2 RS485 Data B Input 5 Ground Screen 3...

Page 11: ...tput always active 7 RTS Input 8 CTS Output The RS232 input may be used instead of the RS485 Loop In where control from a computer is required The software VDM Remote runs on a PC and allows one or mo...

Page 12: ...Input Connector 2 1mm co axial power connector Tip positive shaft negative Voltage 12V Range 9V to 15V DC Current 200mA maximum 4 2 Dimensions 175mm x 125mm x 52mm 4 3 Operating Distances Control Vide...

Page 13: ...I n t e l l i g e n t S e c u r i t y a n d F i r e L t d...

Reviews: