uSwitch and uSwitchPro Installation and Operating Manual
Page 24
Sync Inverts GPIO
If this field is not checked and Sync to Local GPIO is not set to “OFF” the relay state will match whatever the GPIO state is
when it is synchronizing. If “Sync Inverts GPIO is not checkedand Sync to Local GPIO is anything but “OFF” the Relay
state will be the opposite state of the GPIO.
Link Buttons Together
This checkbox is used to assign all the properties for button 1 to button 2 and link them together. When relay buttons are
linked, whenever Button1 is manually pushed both relays transition their states simultaneously (note: depending on the
initial states they can both transition to the same state or opposite states). If timer mode is specified along with linking,
both buttons use Relay1’s timing options.
Force Watchdog Reboot
This Page is accessible only from the menu on the Relay Configuration page. It enables a user to force a Relay in “Ping-
Auto-Reboot Mode” to reboot. Only users with privileges to access the Relay Configuration page will be able to force a
Watchdog Relay Reboot. The screen brings up all relays and enables the user to click on any relay and change its state
or cycle the relay if in Ping-Auto-Reboot mode. However certain relay configurations or states still will not allow the relay
to be forced to a different state (i.e. relays that are synced to a GPIO, slaves to another uSwitch, or in Ping-Auto-Reboot
mode during a Reboot).
Force Watchdog Reboot Page
Summary of Contents for uSwitch
Page 10: ...uSwitch and uSwitchPro Installation and Operating Manual Page 10 ...
Page 14: ...uSwitch and uSwitchPro Installation and Operating Manual Page 14 ...
Page 25: ...uSwitch and uSwitchPro Installation and Operating Manual Page 25 ...
Page 40: ...uSwitch and uSwitchPro Installation and Operating Manual Page 40 ...