7
XTO
/
XTO-IP
Alarm panel
INSTALLATION MANUAL
Arming O/P 1
Arming O/P 2
Existing Host
panel
2.1 Standalone Mode
2.2 XTENDER Mode (From the host)
In this functioning mode,
the XTO-iP panel works as a
standard hybrid alarm system
with 25 wireless peripherals
and 3 programmable inputs.
It is a totally standalone alarm
system.
The panel can be used as standard standalone alarm system but it can also be connected to an existing alarm system capable of
latching a 9-12Vcc* voltage used for its arming/disarming.
When the panel is used in XTENDER mode, the system will only be able to arm and disarm by latching 9-12Vcc to its arming inputs
Arming Input 1 and/or Arming Input 2.
When the voltage switches to 0V, the panel will disarm automatically.
On a programmed panel, you can choose between standalone and XTENDER modes from the menu :
CONFIGURATION
(LVL 4) >
GENERAL PARAMETERS
>
XTENDER
*When using an XTO-iP in XTENDER
mode, the panel has to be powered
by the mains power supply.
2. XTENDER MODE