Properties

Panel Compatibility 

XL, XLL, Visio, XT, XV and their variants

Power Requirements

 

Nominal Voltage 

3.0V

Low battery limit 

2.7V

Battery Type 

Lithium

Quantity 1
Manufacturer and reference 

Duracell, CR123A

Battery life  

Up to 4 years

Current Consumption

 

Standby 

35 µA

Max 

35 mA

Magnet Detection

Detection axis (X1, X2, Y, Z) 
 

Opening detection distance 

20 / 20 / 29 / 41 (mm)

 

Closing detection distance 

4 / 6 / 16 / 24 (mm)

Initialization delay 

10s

Recovery delay 

2s

RF Technology

 S

2

View

®

Radio type 

Spread Spectrum Bidirectional RF

Central Frequency :
 

868MHz  :  IDC200 & (Europe, Africa, Asia)

 

915 MHz FHSS  :  IDC601 (USA, Canada, South America)

 

920MHz FHSS  :  IDC701 (Australia, South America)

Transmission Security 

AES algorithm encryption

Supervision 

Polled signal every 8 minutes

Antenna Integrated

Tamper

 

Wall and cover tamper

Installation / Mounting

Detector

 

 

One screw secures cover to base;  

 

Two screws secure detector to mounting surface.

Magnet

  

 

 

Two screws secure magnet assembly to mounting surface.

Standards

NF EN50131-2-6: 

2008 Grade 2 

RTC 50131-2-6: 

2011

NF EN50131-5-3: 

2005 

NF EN50130-4:  

2011

NF EN50130-5:  

2011 Classe II 

Certifying agency :
CNPP Cert. 

Route de La Chapelle Réanville CS22265
F—27950 SAINT MARCEL
Tel : +33(0)2.32.53.63.63
Fax: +33(0)2.32.53.64.46
Sites Internet : http://www.cnpp.com
Email : [email protected]

Certifying agency :
AFNOR Certification

11, rue François de Pressensé
93571 Saint Denis La Plaine Cedex
Tel : +33(0)1.41.62.80.00
Fax: +33(0)1.49.17.90.00
Sites Internet : http://www.afnor.org 
et http://www.marque-nf.com
Email : [email protected] 

Certifications

 

CE / EN50131 / NF&A2P 

Standards

 EN60950-1:2006+/A11:2009+/A1:2010

EN300220-1 V2.4.1

EN300220-2 V2.4.1

NF&A2P – 2 boucliers –

 suivant le référentiel 

NF324-H58

Matériels de sécurité électroniques, détection d’intrusion
DETECTEUR D’OUVERTURE A CONTACT

Commercial Brand : 

Videofied

Product reference :  

IDC200 

(blanc) 

IDC210 

(brun)

Certification Number :  2123200004A0 

2123200004B0

Others Certifications

 Netherlands 

NCP 

 Singapour 

IDA 

 

South Africa 

ICASA 

915MHz FHSS - IDC601

Certifications  

USA 

FCC Part 15C (FCC47 CFR Part 15) 

 

Canada 

IC (RSS-210 Issue 8)

920MHz FFHS - IDC701

 

Certifications 

Australie 

C-Tick (AS-NZS4268)

© 2

01

3 R

SI V

id

eo T

ec

hn

o

lo

g

ie

s V

id

eo

fie

d

® a

nd M

o

tio

nV

ie

w

er

®  a

re  R

eg

is

te

re

d T

ra

d

em

ar

k o

f R

SI V

id

eo T

ec

hn

o

lo

g

ie

s.

 S

p

ec

ifi

ca

tio

ns s

ub

je

ct t

o c

ha

ng

e w

ith

o

ut n

o

tic

e.

Physical Data

Operating temperature  

-10° to +55°C (14° to 131°F)

Maximum relative humidity 

75%, non-condensing

Material 

Plastic: ABS—ULV0

Magnet 

Alnico 5

Dimensions

 

LxWxD

Body 

3.7 x 1 x 0.86in (95 x 25.8 x 22mm)

Spacer 

2.5 x 0.59 x 0.39in (64 x 15 x 10mm)

Magnet 

2.5 x 0.59 x 0.43in (64 x 15 x 11mm)

Weight: Detector 

38g/1.4oz. – without battery

Physical Protection 

IP31 and IK04

Standards & Certifications

868MHz - IDC200 & IDC210

North American Headquarters

1375 Willow Lake Blvd, Suite 103
Vadnais Heights, MN 55110
USA
E-Mail : [email protected]

EMEA SALES

23, avenue du Général Leclerc
92340 BOURG-LA-REINE
FRANCE
E-Mail : [email protected]

www.videofied.com

4

P R O D U C T   I N S T A L L A T I O N 

S H E E T

Indoor Door Contact  

IDC200/601/701

Summary of Contents for Indoor Door Contact IDC200

Page 1: ...lledenvironment Mount detector on frame and magnet assembly on movable opening door window Donotexceed20mm 6 8 gapbetweendetectorandmagnet Magnetspacermustbeusedtomatchmagnetheightwithdetector toensurecorrectalignmentandfunctionality Donotinstallproductonferromagneticsurfaces The Indoor Door Contact IDC 200 601 701 is a wireless door window contact designed for use with Videofied security systems ...

Page 2: ...nuously indicating good communication with controlpanel 9 PressYES OKtoendradiorangetest thenpressEsc No 10 The display shows AREA ASSIGNMENT AREA 1 Press either arrow button repeatedly until desired AREA number appears then pressYES OK 11 ThedisplayshowsPERIMETERDEVICE PressYES OKorEsc No whicheverisappropriateforthisdevice 12 ThedisplayshowsNAME LOCATION Enter appropriate device name location up...

Page 3: ...ption which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an exp...

Page 4: ...0 00 Fax 33 0 1 49 17 90 00 Sites Internet http www afnor org et http www marque nf com Email certification afnor org Certifications CE EN50131 NF A2P Standards EN60950 1 2006 A11 2009 A1 2010 EN300220 1V2 4 1 EN300220 2V2 4 1 NF A2P 2 boucliers suivant le référentiel NF324 H58 Matériels de sécurité électroniques détection d intrusion DETECTEUR D OUVERTURE A CONTACT CommercialBrand Videofied Produ...

Reviews: