background image

Corner Mounting Holes

Note:  Only two screws are 
used for corner mounting (Left 
or Right)

Corner Mounting

Flat Wall Mounting

Flat Wall 
Mounting 
Holes

The Motion Detector IMD 200/601/701 is a 
wireless, indoor motion detector designed for 
use in a Videofied security system. The motion 
detector includes the following features:

> Lithium batteries for long life
> Standard motion coverage lens (30 ft./9 m 
distance)
> Dual tamper function provides detection of 
both wall and  cover tamper.
> Transmits check-in/status signal every 8 minutes

Product Summary

Installation Guidelines

F

or an easier installation, programming and RF testing should be 

done to check for good communication between the control panel 
and all system devices before mounting. 

Install the detector and other system devices in the following order:

>

 

Programming / RF Testing: Program detector and all other devices 

into the control panel and test RF communication at each intended 
device location to the control panel.

>

 

Mounting: Mount detector at the tested location.

Mounting Rules

>

 Use proper tools and hardware.

>

 Mount indoors in a temperature controlled environment.

>

 Mount detector 2.1 to 2.3 m (6.9 to 7.5 ft.) from the floor.

>

 Respect Top and Bottom side of the Motion Viewer

>

 When possible, mount in a wall corner in order to aim at a complete  

   room

Mount detector on an outside wall, aimed at area to protect.

>

 Do not aim detector at windows, especially those that let in direct  

  sunlight,  or at heat sources such as lamps, fireplaces, radiators,   
  and heating vents.

>

 Do not aim detector at moving objects such as curtains, fans or   

 animals.

>

 Do not cover the Fresnel lens

Indoor Motion Detector IMD 200/601/701

P R O D U C T   I N S T A L L A T I O N   S H E E T

www.videofied.com

Doc. - Ref. 214-IMD
Version :  June 2013

Summary of Contents for IMD 200

Page 1: ... Install the detector and other system devices in the following order Programming RF Testing Program detector and all other devices into the control panel and test RF communication at each intended devicelocationtothecontrolpanel Mounting Mountdetectoratthetestedlocation Mounting Rules Usepropertoolsandhardware Mountindoorsinatemperaturecontrolledenvironment Mountdetector2 1to2 3m 6 9to7 5ft fromt...

Page 2: ...on the keypad until the desired AREA number appears then press YES By default all devices in area 1 will be subject to the entryandexitdelays 11 ThedisplayshowsNAME LOCATION Enter an appropriate device name up to 16 characters The name of the device should describe its intended mounting location or zone PressYES Thedisplaywillshowthedevicenumberandnameforyour verification 12 MounttheIMDonthewall F...

Page 3: ...ce to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving ante...

Page 4: ... Dimensions LxWxD 2 75 x 2 x 1 5in 51 2 x 80 9 x 36 8mm Weight 3 oz 58 g without battery Installation Mounting Mounting Height 2 1 to 2 3m 6 5 to 7 5ft Mounting on Wall On Flat Wall With 2 x Screws In Corner With 2 x Screws Closing of the Casing Closing by clip and screw if required by local legislation Certifications standards 868MHz IMD200 Standards EN60950 1 2006 A11 2009 A1 2010 EN300220 1 V2 ...

Reviews: