P R O D U C T   A P P L I C A T I O N   N O T E

Videofied Upgrade - DSC PC1616

3 .   E X A M P L E   A P P L I C A T I O N   F O R   I N P U T

OBJECTIVE:  Configure any burglary condition on the DSC PC1616 control panel to create a burglary condition on the 
Videofied panel and to report an intrusion signal to the central station with a video from MotionViewer 1

Videofied Programmable Input Configuration - 

TRANSMISSION:  ENABLED

ALARM MODE:  ALARM - Event only is transmitted

INPUT TYPE:  OPEN

EVENT TYPE:  INTRUSION

INPUT NAME:  GE BURG

SIREN MODE:  SIREN

MAPPING:  MOTIONVIEWER 1

DSC PC1616 Output Function Configuration - 

Activated On:  PGM 1 

Segment 1:  01 = Trigger on Fire and Burglary

Summary of Contents for DSC PC1616 Series

Page 1: ...Videofied Upgrade With DSC PC1616 ...

Page 2: ...DE enter you installer code YES www videofied com Using the RIGHT ARROW go to CONFIGURATION and press YES CONFIGURATION GENERAL PARAMETERS XTENDER Press YES on GENERAL PARAMETERS Using the RIGHT ARROW go to XTENDER and press YES ARMING OPTION FROM THE HOST With the display showing ARMING OPTION press YES and use the arrow keys to change it to FROM THE HOST and press YES ENTRY DELAY 0 RIGHT ARROW t...

Page 3: ...requires configuration of one output function for arming and disarming If using both Arming and Mapping input you must ocnfigure both PGM 1 and PGM 2 at the same time ARM FUNCTION Enter selection of 009 Enter 01 01 PGM 1 to trigger on Fire and Burg You must configure PGM 1 at this time Enter 05 05 PGM2 to trigger on Arming Enter to exit Note PGM2 is used for arming due to PGM 1 being limited to 50...

Page 4: ...ED Keypad BLK Keypad YEL Keypad GRN Keypad PGM 1 PGM 2 12v Power Source DSC PC1616 Terminal strip 2 T R I G G E R A N I N P U T O N V I D E O F I E D P A N E L W I T H D S C P C 1 6 1 6 P A N E L STEP 1 CONFIGURE INPUT ON VIDEOFIED CONTROL PANEL DATE TIME DISARMED LVL 1 ACCESS LEVEL 4 RIGHT ARROW to ACCESS LEVEL and press YES RIGHT ARROW to ACCESS LVL 4 and press YES When prompted with BADGE OR CO...

Page 5: ... arrow keys to choose Closed and press YES EVENT TYPE RIGHT ARROW to EVENT TYPE and press YES Use the arrow keys to select the event the panel should report to the central station when the input is triggered and press YES INPUT NAME RIGHT ARROW to INPUT NAME and press YES Use the alphanumeric keypad to define a logical name to the input and press YES SIREN MODE RIGHT ARROW to SIREN MODE and press ...

Page 6: ...rigger on Fire and Burglary Enter to exit Wiring Diagram Using a Videofied Programmable Input Prog Out Com Prog Output 2 Prog Output 1 Ref GND Prog Input 3 Prog Input 2 Prog Input 1 Ref Ref GND Arming Input 2 Arming Input 1 Ref PWR PWR Videofied Panel Terminal Strip SPDT 4 Terminal Relay NO C POS NEG AC AC Aux Aux Bell Bell RED Keypad BLK Keypad YEL Keypad GRN Keypad PGM 1 PGM 2 12v Power Source D...

Page 7: ... D U C T A P P L I C A T I O N N O T E Videofied Upgrade DSC PC1616 3 E X A M P L E A P P L I C A T I O N F O R I N P U T OBJECTIVE Configure any burglary condition on the DSC PC1616 control panel to create a burglary condition on the Videofied panel and to report an intrusion signal to the central station with a video from MotionViewer 1 Videofied Programmable Input Configuration TRANSMISSION ENA...