STEP 2 - Wire and configure DSC PC1616 Open Collector Output
P R O D U C T A P P L I C A T I O N N O T E
Videofied Upgrade - DSC PC1616
Connect one SPDT Relay Module to the DSC PC1616 Series Control Panel
Enter Installer / Programming Mode
Enter
*
8 then installer code
Configure Output Function:
Videofied Upgrade to DSC PC1616 series control panels requires
configuration of one output function for arming and disarming. If using both Arming and Mapping
input you must ocnfigure both PGM 1 and PGM 2 at the same time.
ARM FUNCTION
Enter selection of “009”
Enter 01 - 01 = PGM 1 to trigger on Fire and Burg - You must configure PGM 1 at this time
Enter 05 - 05 = PGM2 to trigger on Arming
Enter # # to exit
Note: PGM2 is used for arming due to PGM 1 being limited to 50mA
SPDT 4 Terminal Relay
NO
C
POS
+
NEG
-
AC
AC
Aux +
Aux -
Bell +
Bell -
RED-Keypad
BLK-Keypad
YEL-Keypad
GRN-Keypad
PGM 1
PGM 2
DSC PC1616 Terminal strip