background image

Electrical Data

Panel Compatibility 

Xl, Visio, XT, XTIP

Power requirements  

 Three 3.6 V Lithium batteries

      Nominal Voltage 

3V

      Low Battery Limit 

2.7V

      Battery type 

SAFT AA Lithium, LS14500

      Battery life (estimated) 

Up to 4 years

RF technology 

S

2

View

®

Radio type 

Spread Spectrum Bidirectional RF

Operating frequency 

915 MHz (US) 

Transmission security  

AES algorithm encryption

Supervision 

Panel polls devices every 8 minutes

Antenna Integrated

Tamper detection 

Wall and cover tampered

Camera sensor type 

CMOS black and white

Camera resolution 

320 x 240 pixels

Camera sensitivity 

0.2 lux

Camera lens 

Wide angle 85°

Camera response  

less than 100 milliseconds  

 

after PIR detection

Video sequence in intrusion  

5 frames/s for 10 seconds

Night illumination 

2 infrared LEDs

Night illumination switching 

Automatic

Night illumination distance 

UP to 14 ft./ 4.5 m

Motion detector technology 

Passive infrared DSP

Motion detector type 

Dual element

Motion Lens 

Fresnel

Motion Detection angle 

 85°

Motion Detection distance 

Up to 40 ft./12 m

Motion Detection pattern  

24 facets

Operating temperature 

14° - 104° F (-10° - 40° C)

Maximum relative humidity 

75%, non-condensing

UL Listings 

FCC Part 15C

 

1023 (applied for)

Physical Data

Material ABS—ULV0 

Dimensions  

(LxWxD): 3-1/2 in. x 2-3/4 in. x 2-3/4 in.

 

(89 mm x 70 mm x 70 mm)

Weight 

5.3 oz./150 g (without batteries)

Installation/Mounting

Camera/Base   

One screw secures camera to base; 

 

two screws secure camera base to  

 

mounting surface, flat or corner mount.

Mounting Height 

6.9-7.5 Feet (2.1-2.3 meters)

Indoor MotionViewer DCV601

I N S T A L L A T I O N   D A T A   S H E E T

www.videofied.com

Summary of Contents for DCV601

Page 1: ...alphanumeric keypad proceed through menus until the display shows ADD A NEW DEVICE 5 Press Yes The display shows PRESS PROGRAM BUTTON OF DEVICE 6 Press and release program button on camera using a paper clip end The camera LED flashes Wait for keypad display to show CAMERA 1 25 PROGRAMMED 7 Press Yes The display shows RADIO RANGE TEST Press Yes again The camera LED starts flashing and keypad displ...

Page 2: ... such as curtains fans or animals 1 Separate base from camera 2 Hold camera base against mounting surface and mark the two appropriate mounting holes 3 Drill pilot holes and install anchors where needed 4 Place base on mounting surface so holes line up with pilot holes anchors and secure base with appropriate screws 5 Install batteries into camera observing correct polarity 6 Attach camera to base...

Page 3: ...on 5 frames s for 10 seconds Night illumination 2 infrared LEDs Night illumination switching Automatic Night illumination distance UP to 14 ft 4 5 m Motion detector technology Passive infrared DSP Motion detector type Dual element Motion Lens Fresnel Motion Detection angle 85 Motion Detection distance Up to 40 ft 12 m Motion Detection pattern 24 facets Operating temperature 14 104 F 10 40 C Maximu...

Page 4: ...at interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and recei...